Specifications

LC1E06004U7IN — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationResistive load
LC1E06004U7IN — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-1
LC1E06004U7IN — Contacts & Poles
ParameterValue
Pole configuration4P
LC1E06004U7IN — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E06004U7IN — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5
LC1E06004U7IN — Mechanical
ParameterValue
Width45 mm
Height74 mm
Depth80 mm

Product details

The Schneider Electric LC1E06004U7IN is a 4-pole (4NO) contactor from the Easy TeSys Control range, rated for resistive loads in AC-1 utilisation category at 20 A up to 415 V. It is designed for panel mounting on a DIN rail or plate, with an IP2X degree of protection per IEC 60529. The contactor complies with EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, and the corresponding GB/T 14048 series standards, making it suitable for industrial control panels requiring certified switching of resistive loads.

The AC-1 rating of 20 A at ≤415 V defines the continuous resistive load the main poles can carry and switch. For motor or inductive loads, a derating to the appropriate AC-3 or AC-4 category would apply — this part is specified for resistive duty only. The contactor's non-overlap time of 1.5 ms on both energisation and de-energisation between NC and NO contacts ensures that make and break transitions do not short-circuit control logic — critical when interlocking safety circuits or reversing starters. Rated for operation at altitudes up to 3000 m and ambient temperatures from -5 °C to 55 °C (storage -60 °C to 80 °C), with protective treatment TH (pollution degree 3) per IEC 60068. The 850 °C fire resistance per IEC 60695-2-1 supports use in flame-retardant panel designs.

Because the LC1E06004U7IN is obsolete, a buyer specifying it for a new design should evaluate a current-production replacement. The Easy TeSys Control range includes active equivalents with similar pole configurations and AC-1 ratings; contact our sourcing desk with your load details for a cross-reference recommendation.

Depth of 80 mm should be checked against enclosure depth, especially when wiring with ferrule-ended conductors.

Frequently asked questions

What is the physical size of this contactor?

Width 45 mm, height 74 mm, depth 80 mm. It mounts on a DIN rail or plate.

MPN