Schneider Electric Easy TeSys Control, LC1E06008V7IN, 4P (2NO+2NC) contactor, AC-1 ≤415V 20A, 400V coil.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1E06008V7IN — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationResistive load
LC1E06008V7IN — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-1
LC1E06008V7IN — Contacts & Poles
ParameterValue
Pole configuration4P
LC1E06008V7IN — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E06008V7IN — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5
LC1E06008V7IN — Mechanical
ParameterValue
Width45 mm
Height74 mm
Depth80 mm

Product details

The Schneider Electric LC1E06008V7IN is a 4-pole (2NO+2NC) contactor from the Easy TeSys Control range, rated for 20 A in AC-1 utilisation category at up to 415 V. This means it's designed specifically for resistive loads — heaters, lighting banks, or similar non-inductive circuits — not for motor starting. The AC-1 rating is the headline figure here: it tells you the contactor can make and break resistive current at that level without accelerated wear. The 400 V coil is standard for 400 VAC control circuits common across European panel builds.

The 20 A AC-1 rating governs the resistive load it can switch. Don't confuse this with an AC-3 motor rating — this contactor isn't sized for inductive motor starts. The 4-pole configuration with 2 normally-open and 2 normally-closed contacts gives flexibility for switching multiple load circuits or interlocking control circuits. The 1.5 ms non-overlap time between NC and NO contacts on both energisation and de-energisation is a safety feature: it guarantees that the NC contacts open before the NO contacts close (and vice versa), preventing momentary short-circuits in interlocking applications.

Operating altitude is rated to 3000 m, so it's fine for most installations except high-altitude sites above that.

The 850 °C fire resistance rating per IEC 60695-2-1 means the contactor housing won't propagate a flame under fault conditions, which is a requirement for most industrial control panels.

Frequently asked questions

What are the key ratings for this contactor?

It is a 4-pole (2NO+2NC) contactor rated 20 A in AC-1 utilisation category at up to 415 V, with a 400 V coil. It is designed for resistive loads only, not motor starting.

What standards does this contactor comply with?

It complies with EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, and the Chinese GB/T 14048.1, GB/T 14048.4, and GB/T 14048.5 standards. It also has 850 °C fire resistance per IEC 60695-2-1.

How do I source this obsolete part?

Since it is obsolete, sourcing is through surplus or broker channels. We can source it to order against an RFQ; availability and lead time depend on current inventory at the time of request.