Schneider Electric LC1E0601F5 — Contactors

Schneider Electric LC1E0601F5 Easy TeSys Contactor, 3P, AC-3

MPNLC1E0601F5
Active

Schneider Electric Easy TeSys Control contactor, 3P (3 NO), AC-3 <=440V 6A, 110V AC coil, DIN rail / plate mount.

$11.17Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LC1E0601F5 — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationMotor control Resistive load
LC1E0601F5 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-3 AC-3e AC-1
LC1E0601F5 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1E0601F5 — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068-2-30
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E0601F5 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ
LC1E0601F5 — Mechanical
ParameterValue
Width45 mm
Height74 mm
Depth80 mm

Product details

The Schneider Electric LC1E0601F5 is a 3-pole (3 NO) contactor from the Easy TeSys Control range, rated for AC-3 motor duty at 6 A up to 440 V, with a 110 V AC coil. It switches motor loads in control panels, resistive loads, and general power circuits where the coil voltage matches the 110 V AC control supply. Rated operational voltage covers power circuit switching; the control circuit maintains a minimum 10 MΩ isolation. The contactor carries EN/IEC 60947-4-1 and GB/T 14048.4 approvals for motor-starting duty, plus 850 °C glow-wire fire resistance per IEC 60695-2-1.

The 45 mm width and 74 mm height fit standard panel density; 80 mm depth clears most enclosure backplates. IP2X finger protection per IEC 60529 means no additional guarding needed for the contactor body inside a closed panel.

Frequently asked questions

What are the key ratings I need to check for fit?

The contactor is rated AC-3 at 6 A up to 440 V with a 110 V AC coil. The 3-pole (3 NO) configuration switches motor loads; the AC-3 duty class means it handles motor starting current without welding contacts. Verify that your control voltage is 110 V AC and the motor full-load current does not exceed 6 A in AC-3 duty.

What standards does this contactor comply with?

It complies with EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, GB/T 14048.1, GB/T 14048.4, GB/T 14048.5, and the glow-wire test per EN/IEC 60335-1 Clause 30.2 and EN/IEC 60335-2-40 Annex JJ. Fire resistance is 850 °C per IEC 60695-2-1.

MPN
LC1E0601F5