Skip to main content
Schneider Electric LC1E0601F6 — Contactors

Schneider LC1E0601F6 Easy TeSys Contactor, 6A AC-3, 110V AC

MPNLC1E0601F6
Obsolete

Schneider Electric Easy TeSys Control, LC1E0601F6, 3P contactor, AC-3/AC-3e 6A ≤440V, 110V AC coil 60Hz, 1NC auxiliary contact.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1E0601F6 — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationMotor control Resistive load
LC1E0601F6 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-3 AC-3e AC-1
LC1E0601F6 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1E0601F6 — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068-2-30
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E0601F6 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ
LC1E0601F6 — Mechanical
ParameterValue
Width45 mm
Height74 mm
Depth80 mm

Product details

The LC1E0601F6 is a 3-pole contactor from the Easy TeSys Control range, rated for motor control in AC-3 and AC-3e duty at 6 A up to 440 V, plus resistive loads in AC-1. The coil is 110 V AC at 60 Hz, and it carries one normally-closed auxiliary contact. The AC-3e rating adds an energy-efficiency classification for those same motor loads.

The 1.5 ms non-overlap time between NC and NO contacts is a standard safety feature for contactors — it guarantees that the NC and NO poles never close simultaneously during coil energisation or de-energisation, which prevents a momentary short across the load. The 3000 m altitude rating without derating covers most installations outside high-altitude mining or mountain sites.

It also meets EN/IEC 60335-1 Clause 30.2 and -2-40 Annex JJ for appliance applications, and the 850 °C glow-wire test per IEC 60695-2-1 for fire resistance.

Frequently asked questions

What are the key ratings for the LC1E0601F6?

It is a 3-pole contactor rated 6 A in AC-3/AC-3e motor duty at ≤440 V, with a 110 V AC 60 Hz coil and one normally-closed auxiliary contact. It also covers AC-1 resistive loads.

What mounting options does this contactor have?

It mounts on DIN rail or directly on a plate, which covers standard panel integration.

What compliance documentation is available for this part?

It is certified to EN/IEC 60947-1, -4-1, -5-1, GB/T 14048.1/4/5, and EN/IEC 60335-1 Clause 30.2 and -2-40 Annex JJ. It also meets the 850 °C glow-wire test per IEC 60695-2-1.

MPN