Skip to main content
Schneider Electric LC1E09004N7IN — Contactors

Schneider Electric LC1E09004N7IN Easy TeSys Contactor, 4P 25

MPNLC1E09004N7IN
Obsolete

Schneider Electric Easy TeSys Control LC1E09004N7IN, 4P(4NO) contactor, AC-1 ≤415V 25A at 415V, DIN rail/plate mount, obsolete.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1E09004N7IN — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationResistive load
LC1E09004N7IN — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-1
LC1E09004N7IN — Contacts & Poles
ParameterValue
Pole configuration4P
LC1E09004N7IN — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E09004N7IN — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5
LC1E09004N7IN — Mechanical
ParameterValue
Width45 mm
Height74 mm
Depth80 mm

Product details

It is rated for AC-1 utilisation category at 25 A up to 415 V, meaning it is designed for switching resistive loads — heaters, lighting banks, or other non-inductive circuits — in control panels. The IP2X degree of protection means the enclosure resists finger contact but is not sealed against dust or moisture — it belongs inside a cabinet, not on a washdown line.

The 25 A AC-1 rating is the headline number, but note the duty: AC-1 is resistive load. If your circuit drives motors, transformers, or other inductive loads, the contactor's AC-3 or AC-4 rating would be lower — this part does not carry those categories in its listing. The 4NO pole configuration is fixed; there is no changeover (NC) pole on this variant. The non-overlap time of 1.5 ms on both energisation and de-energisation, guaranteed between NC and NO contacts, is a safety-relevant parameter for interlocking circuits where a make-before-break condition must be avoided. The protective treatment TH (pollution degree 3) per IEC 60068 means the contactor is treated for tropical humidity and moderate industrial atmospheres — condensation and conductive dust are expected in the environment, and the part is designed to withstand them without conformal coating.

Frequently asked questions

What are the key ratings for this contactor?

It is a 4-pole, 4NO contactor rated 25 A in AC-1 (resistive load) at up to 415 V. Mounting is DIN rail or plate, with a 45 mm width. It complies with EN/IEC 60947-1, -4-1, -5-1 and the corresponding GB/T standards.

What compliance documentation is available for this part?

The contactor carries approvals to EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, and the Chinese GB/T equivalents GB/T 14048.1, GB/T 14048.4, GB/T 14048.5. Fire resistance is rated at 850 °C per IEC 60695-2-1. Protective treatment is TH (pollution degree 3) per IEC 60068.

MPN
LC1E09004N7IN