Skip to main content
Schneider Electric LC1E09008F7IN — Contactors

Schneider LC1E09008F7IN Easy TeSys Contactor, 40A AC-1, 110V

MPNLC1E09008F7IN
Active

Schneider Electric Easy TeSys contactor, LC1E09008F7IN, 4P (2 NO + 2 NC), AC-1 ≤415 V 40 A, 110 V AC coil, DIN-rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1E09008F7IN — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationResistive load
LC1E09008F7IN — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-1
LC1E09008F7IN — Contacts & Poles
ParameterValue
Pole configuration4P
LC1E09008F7IN — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E09008F7IN — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5
LC1E09008F7IN — Mechanical
ParameterValue
Width45 mm
Height74 mm
Depth80 mm

Product details

The Schneider Electric LC1E09008F7IN is a 4-pole Easy TeSys contactor with a 110 V AC coil, wired 2 NO + 2 NC. It is rated for 40 A in AC-1 utilisation category at up to 415 V, making it a straight resistive-load switching part — heaters, ovens, incandescent lighting banks, or any load where inrush stays under 1.5× running current. Depth is 80 mm, height 74 mm — no surprises for an existing Easy TeSys cutout.

What the AC-1 rating means for your BOM line

AC-1 is the utilisation category for resistive or slightly inductive loads — the contactor sees near-zero inrush and switches at power factor near unity. The 40 A figure at 415 V is the thermal current (Ith) under those conditions. If your load is a motor (AC-3) or a transformer (AC-6a), this contactor is not the right pick; in those categories the make/break current is far lower. For a resistive bank or a resistance heater string, this is the correct duty class and the rating is honest at 40 A.

IP2X finger-safe front.

Mounts on DIN rail or plate. The 4-pole layout with 2 NO + 2 NC gives you one normally-open and one normally-closed pair on each side of the contactor — useful for interlocking or status feedback without adding a separate auxiliary block. Permissible ambient during operation is -5 to 55 °C; storage range is -60 to 80 °C. Vibration resistance: 1.5 Gn open, 3 Gn closed across 5–300 Hz. Shock resistance: 7 Gn open, 10 Gn closed for 11 ms.

Frequently asked questions

What are the key ratings for this contactor?

40 A at 415 V in AC-1 utilisation category (resistive load). 4 poles configured 2 NO + 2 NC. Coil is 110 V AC. Mounts on DIN rail or plate, 45 mm wide.

What standards does this contactor comply with?

EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, and the Chinese GB/T 14048 equivalents. Fire resistance to 850 °C per IEC 60695-2-1.

Can this contactor switch motor loads?

No — it is rated only for AC-1 (resistive) duty. For motor starting (AC-3), a different contactor with a higher make/break capacity is required.

MPN
LC1E09008F7IN