Schneider Electric LC1E0910E7 — Contactors

Schneider Electric LC1E0910E7 Easy TeSys Contactor, 9A AC-3,

MPNLC1E0910E7
Active

Schneider Electric Easy TeSys Control contactor, LC1E0910E7, 3P(3NO), AC-3 <=440V 9A, 48V AC 50/60Hz coil, 1NO auxiliary contact.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1E0910E7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationMotor control Resistive load
LC1E0910E7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-3 AC-3e AC-1
LC1E0910E7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1E0910E7 — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068-2-30
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E0910E7 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ
LC1E0910E7 — Mechanical
ParameterValue
Width45 mm
Height74 mm
Depth80 mm

Product details

The Schneider Electric LC1E0910E7 is a 3-pole contactor from the Easy TeSys Control range, rated 9 A in AC-3 utilisation category at up to 440 V.

Ambient operation from -5 to 55 °C, storage from -60 to 80 °C, and it runs at altitudes up to 3000 m without derating.

AC-1 (resistive) rating is higher, but for motor loads, AC-3 is the one to match to the motor FLA.

Sourcing reality

Active and widely available through distribution. No obsolescence risk. The 48 V AC coil is less common than 24 V DC or 230 V AC, so confirm your control voltage matches before committing the BOM line.

Frequently asked questions

What compliance documentation is available for this part?

The contactor is certified to EN/IEC 60947-4-1 and EN/IEC 60947-5-1, with GB/T equivalents. Fire resistance is tested to 850 °C glow-wire. Protective treatment TH (pollution degree 3) is confirmed. RoHS and REACH declarations are standard from Schneider Electric.

MPN
LC1E0910E7