Skip to main content
Schneider Electric LC1E0910F7 — Contactors

Schneider LC1E0910F7 Easy TeSys Contactor, 3P, 9A, 110V AC C

MPNLC1E0910F7
Obsolete

Schneider Electric Easy TeSys Control LC1E0910F7, 3-pole contactor, 9 A AC-3/AC-3e at ≤440 V, 110 V AC 50/60 Hz coil, 1 NO auxiliary contact.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1E0910F7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationMotor control Resistive load
LC1E0910F7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-3 AC-3e AC-1
LC1E0910F7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1E0910F7 — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068-2-30
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E0910F7 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ
LC1E0910F7 — Mechanical
ParameterValue
Width45 mm
Height74 mm
Depth80 mm

Product details

Part identity and key ratings

It carries a 9 A rating in AC-3 and AC-3e utilisation categories at ≤440 V, with a 110 V AC 50/60 Hz coil and one normally-open auxiliary contact built in.

The AC-3e rating extends that to energy-efficient IE3/IE4 motors with slightly different switching characteristics. For purely resistive loads (AC-1), the contactor can carry a higher current, but the 9 A AC-3 figure is the one that decides fit for most motor-control BOM lines.

Fire resistance tested to 850 °C per IEC 60695-2-1. Protective treatment TH (pollution degree 3) per IEC 60068-2-30 means it's suitable for environments with high humidity and some condensation — typical for industrial control panels in non-conditioned spaces.

Frequently asked questions

What are the key ratings for this contactor?

The LC1E0910F7 is a 3-pole contactor rated 9 A in AC-3/AC-3e at ≤440 V, with a 110 V AC 50/60 Hz coil and one normally-open auxiliary contact.

What standards does the LC1E0910F7 comply with?

It complies with EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, and the corresponding GB/T 14048 series standards. Fire resistance is tested to 850 °C per IEC 60695-2-1.

MPN
LC1E0910F7