Schneider Electric LC1E0910Q7 — Contactors

Schneider LC1E0910Q7 Easy TeSys Contactor, 9A AC-3, 380V Coi

MPNLC1E0910Q7
Active

Schneider Electric Easy TeSys Control series, LC1E0910Q7, 3-pole contactor, 9A AC-3 at ≤440V, 380V AC 50/60Hz coil, 1NO auxiliary contact.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1E0910Q7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationMotor control Resistive load
LC1E0910Q7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-3 AC-3e AC-1
LC1E0910Q7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1E0910Q7 — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068-2-30
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E0910Q7 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ
LC1E0910Q7 — Mechanical
ParameterValue
Width45 mm
Height74 mm
Depth80 mm

Product details

Part Status and Sourcing Reality

Specification Summary for Fit Verification

This is a 3-pole contactor (3NO main poles) from the Easy TeSys Control range, rated 9 A in AC-3 utilisation category at operational voltage up to 440 V. The coil is 380 V AC, 50/60 Hz. One normally-open auxiliary contact is included on the front. The AC-3 rating of 9 A is the figure that governs switching of standard squirrel-cage motors — this is the rating to match against the motor full-load current on the BOM line.

The contactor is fully compliant with EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, and the corresponding GB/T standards. Permissible ambient air temperature around the device is -20 to 70 °C at Uc, with operation limited to -5 to 55 °C. Storage range is -60 to 80 °C.

Mechanical and Switching Characteristics

This ensures break-before-make operation for interlocking circuits — critical for reversing or star-delta starters where contact overlap would cause a phase-to-phase fault. Mechanical robustness is specified for vibration: 1.5 Gn (5–300 Hz) when open, 3 Gn (5–300 Hz) when closed. Shock resistance: 7 Gn for 11 ms when open, 10 Gn for 11 ms when closed. These figures confirm suitability for installation on machinery subject to moderate vibration.

Frequently asked questions

What replaces the LC1E0910Q7?

No official successor order code is listed by the manufacturer for this part. A replacement must be evaluated against the original specification: 3-pole, 9 A AC-3 at ≤440 V, 380 V AC 50/60 Hz coil, 1NO auxiliary contact. Contact our sourcing team with the application details for a cross-reference proposal.

What are the key ratings for fit verification?

The critical ratings are: 9 A in AC-3 (motor switching) at ≤440 V, 380 V AC 50/60 Hz coil voltage, 3-pole configuration with 1NO auxiliary contact. Mounting is DIN rail or plate, 45 mm width.

What compliance standards does this contactor meet?

It is compliant with EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, and the corresponding GB/T standards. Fire resistance is verified at 850 °C per IEC 60695-2-1. Protective treatment is TH (pollution degree 3).

MPN
LC1E0910Q7