Skip to main content
Schneider Electric LC1E12004M5WB — Contactors

Schneider Electric LC1E12004M5WB Easy TeSys Contactor, 25 A

MPNLC1E12004M5WB
Obsolete

Schneider Electric Easy TeSys Control LC1E12004M5WB, 4-pole contactor, 25 A AC-1, 220 V AC 50 Hz coil, screw clamp terminals, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1E12004M5WB — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationResistive load
LC1E12004M5WB — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: <= 690 V AC 50/60 Hz
Utilisation categoryAC-1
LC1E12004M5WB — Contacts & Poles
ParameterValue
Pole configuration4P
LC1E12004M5WB — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)
Protective treatment / pollution degreeTH conforming to IEC 60068-2-30
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E12004M5WB — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5
LC1E12004M5WB — Mechanical
ParameterValue
Width45 mm
Height74 mm
Depth80 mm

Product details

The Schneider Electric LC1E12004M5WB is a 4-pole contactor from the Easy TeSys Control range, rated for 25 A in AC-1 utilisation category at ≤ 440 V AC — meaning it is sized for resistive loads such as heaters or lighting banks, not motor starting. The 4 NO pole composition gives you four normally-open main contacts, all switching the same phase or load group. The coil is 220 V AC at 50 Hz, wide-range control circuit type, with a drop-out threshold of 0.3–0.6 Uc and pick-up of 0.7–1.25 Uc across -5 to 55 °C. Inrush power is 95 VA at 50 Hz cos φ 0.75; steady-state heat dissipation runs 2–3 W on the control side.

The 45 mm wide footprint and 74 mm height fit standard 4-pole contactor slots in distribution boards or control enclosures. Depth is 80 mm, so allow clearance for wiring and the screw clamp terminals. Screw clamp terminals accept 1–4 mm² flexible with cable end or solid on the power circuit, and 1–2.5 mm² on the control circuit. Tightening torque is 1.2 N·m for both power and control terminals. IP20 finger-safe protection means it is suitable for enclosed panels where operators do not contact live parts.

Electrical performance and durability

Rated insulation voltage is 690 V, with a rated breaking capacity of 96 A at 440 V and a making capacity of 120 A at 440 V AC per IEC 60947-4-1. Electrical durability is 300,000 cycles under AC-1 load; mechanical durability is 10 million cycles. Maximum operating rate is 1,800 cycles per hour at 60 °C. Associated fuse rating is 25 A gG at ≤ 690 V, coordination type 1. The contactor withstands vibration of 3 Gn closed and shock of 10 Gn closed, making it mechanically robust for industrial environments.

Frequently asked questions

What are the key ratings for this contactor?

Rated operational current is 25 A at ≤ 440 V AC in AC-1 utilisation category. Coil voltage is 220 V AC 50 Hz. It has 4 normally-open poles and screw clamp terminals. Rated insulation voltage is 690 V.

What standards does the LC1E12004M5WB comply with?

It complies with EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, and the Chinese GB/T equivalents 14048.1, 14048.4, and 14048.5.

How is this contactor mounted and what are its dimensions?

It mounts on DIN rail or directly to a plate. Dimensions are 45 mm wide, 74 mm high, and 80 mm deep.

MPN
LC1E12004M5WB