Skip to main content
Schneider Electric LC1E12008E7IN — Contactors

Schneider Electric LC1E12008E7IN Easy TeSys Contactor, 4P AC

MPNLC1E12008E7IN
Obsolete

Schneider Electric Easy TeSys Control, contactor LC1E12008E7IN, 4P (2 NO + 2 NC), AC-1 ≤415 V 45 A, 48 V AC coil, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1E12008E7IN — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationResistive load
LC1E12008E7IN — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-1
LC1E12008E7IN — Contacts & Poles
ParameterValue
Pole configuration4P
LC1E12008E7IN — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E12008E7IN — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5
LC1E12008E7IN — Mechanical
ParameterValue
Width45 mm
Height74 mm
Depth80 mm

Product details

The Schneider Electric LC1E12008E7IN is a 4-pole Easy TeSys Control contactor configured 2 NO + 2 NC, rated AC-1 for resistive loads at 45 A up to 415 V, with a 48 V AC coil. It is now classified as obsolete per the manufacturer.

AC-1 utilisation category means this contactor is specified for resistive loads (heating, lighting, non-inductive) at the full 45 A. The 4-pole arrangement with two normally-open and two normally-closed power poles gives flexibility for switching separate load circuits or implementing interlocking without external auxiliaries. The 48 V AC coil suits control circuits common in older panel designs or step-down transformer supplies. Non-overlap time of 1.5 ms on both energisation and de-energisation between NC and NO contacts ensures break-before-make for interlocking applications. IP2X finger protection on the contactor body is adequate for enclosed panels but does not resist washdown.

Fire resistance tested to 850 °C per IEC 60695-2-1. Protective treatment TH (pollution degree 3) per IEC 60068 suits industrial environments with moderate condensation.

Frequently asked questions

What are the key ratings of the LC1E12008E7IN?

4-pole contactor (2 NO + 2 NC), AC-1 utilisation category, 45 A at ≤415 V, 48 V AC coil. DIN rail or plate mount, 45 mm wide.

What standards does the LC1E12008E7IN comply with?

EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, and the Chinese GB/T 14048 series. Fire resistance to 850 °C per IEC 60695-2-1.

How do I source the LC1E12008E7IN now that it is obsolete?

We can source it through surplus and broker channels. Submit an RFQ for a quote on available inventory.

MPN
LC1E12008E7IN