Skip to main content
Schneider Electric LC1E12008M5WBIN — Contactors

Schneider LC1E12008M5WBIN Easy TeSys Contactor, 32 A AC-1, 2

MPNLC1E12008M5WBIN
Active

Schneider Electric Easy TeSys Control LC1E12008M5WBIN, 4-pole contactor, 32 A AC-1, 220 VAC 50 Hz coil, screw clamp terminals, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1E12008M5WBIN — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationResistive load
LC1E12008M5WBIN — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: <= 690 V AC 50/60 Hz
Utilisation categoryAC-1
LC1E12008M5WBIN — Contacts & Poles
ParameterValue
Pole configuration4P
LC1E12008M5WBIN — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
Operating altitude3000 m
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)
Protective treatment / pollution degreeTH conforming to IEC 60068
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E12008M5WBIN — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5
LC1E12008M5WBIN — Mechanical
ParameterValue
Width45 mm
Height74 mm
Depth80 mm

Product details

The Schneider Electric LC1E12008M5WBIN is a 4-pole contactor from the Easy TeSys Control range, rated for 32 A in AC-1 utilisation category (resistive load) at up to 415 V AC. That 32 A figure is the current it can carry continuously in a resistive heating or lighting circuit — not a motor-starting rating. The coil is 220 V AC at 50 Hz, with a wide-range control circuit that pulls 95 VA inrush at 20 °C and settles to 2–3 W heat dissipation. It's built to EN/IEC 60947-4-1 and 60947-5-1, so it's certified for both power switching and control-circuit isolation in the same package.

The contactor has 2 normally-open and 2 normally-closed power poles — that's a 4-pole configuration common for switching three-phase plus neutral or dual circuits. The auxiliary contact composition is listed as "without", so there's no built-in aux block; if you need feedback to a PLC or a seal-in circuit, you'll add a side-mount aux contact separately. The associated fuse recommendation is 32 A gG at ≤ 690 V, coordination type 1, meaning the contactor is protected by that fuse and may need replacement after a short-circuit event.

Screw-clamp terminals on both power and control circuits accept solid up to 6 mm² or flexible with ferrule up to 4 mm². Tightening torque is 1.2 N.m for both circuits — a common value, so no special tool needed. IP20 finger-safe front, but the terminals are live when wired — standard panel practice.

Frequently asked questions

What are the key ratings I need to check for fit?

The rated operational current is 32 A in AC-1 (resistive load) at ≤ 415 V AC. The coil is 220 V AC 50 Hz. It is a 4-pole contactor with 2 NO + 2 NC power poles and no built-in auxiliary contacts.

What standards does this contactor comply with?

It complies with EN/IEC 60947-1, 60947-4-1, and 60947-5-1, plus the Chinese GB/T equivalents. Overvoltage category III and pollution degree 3 are specified for industrial panel use.

MPN
LC1E12008M5WBIN