Schneider Electric EasyPact TVS contactor, 3P (3 NO), AC-3 12A at ≤440 V, 380 V AC coil, DIN rail/plate mount, 45 mm wide.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

LC1E1201Q5 — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationMotor control Resistive load
LC1E1201Q5 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-3 AC-3e AC-1
LC1E1201Q5 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1E1201Q5 — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068-2-30
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E1201Q5 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ
LC1E1201Q5 — Mechanical
ParameterValue
Width45 mm
Height74 mm
Depth80 mm

Product details

That AC-3 rating covers the standard induction-motor starting and stopping profile — the contactor is sized for a motor drawing 12 A under load, not just the locked-rotor inrush.

The 45 mm width keeps the footprint tight in a crowded enclosure — three of these sit side by side in a standard 140 mm backplate bay. Depth is 80 mm, height 74 mm, so it clears most 100 mm gland-plate depths without a spacer.

Fire resistance tested to 850 °C per IEC 60695-2-1. Protective treatment TH (pollution degree 3) per IEC 60068-2-30 means it handles humid, mildly corrosive environments — typical for unheated control cabinets in temperate climates. IP2X finger protection on the contactor body.

Frequently asked questions

What are the key ratings for this contactor?

Three-pole, normally open. AC-3 rating is 12 A at ≤440 V. Coil is 380 V AC. Utilisation categories cover AC-3, AC-3e, and AC-1 (resistive).

What compliance documentation does Schneider provide for the LC1E1201Q5?

The contactor is certified to EN/IEC 60947-1, -4-1, -5-1, and the corresponding GB/T standards. Fire resistance is tested to 850 °C per IEC 60695-2-1. Protective treatment TH (pollution degree 3) per IEC 60068-2-30 is also listed.

MPN
LC1E1201Q5