Schneider Electric LC1E1201R6 — Contactors

Schneider LC1E1201R6 Easy TeSys Contactor, 3P, 12A AC-3, 440

MPNLC1E1201R6
Obsolete

Schneider Electric Easy TeSys Control, LC1E1201R6, 3P(3NO) contactor, AC-3/AC-3e 12A ≤440V, 440V AC 60Hz coil, 1NC auxiliary contact.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

LC1E1201R6 — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationMotor control Resistive load
LC1E1201R6 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-3 AC-3e AC-1
LC1E1201R6 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1E1201R6 — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068-2-30
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E1201R6 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ
LC1E1201R6 — Mechanical
ParameterValue
Width45 mm
Height74 mm
Depth80 mm

Product details

The Schneider Electric LC1E1201R6 is a 3-pole (3NO) contactor from the Easy TeSys Control range, rated for AC-3 and AC-3e motor switching at 12 A up to 440 V, with a 440 V AC 60 Hz coil and one NC auxiliary contact built in. It also carries an AC-1 utilisation category for resistive load switching, and meets EN/IEC 60947-4-1 (contactor/motor starter) and EN/IEC 60947-5-1 (control circuit device) standards, plus GB/T equivalents and the glow-wire test at 850 °C per IEC 60695-2-1.

The AC-3e variant covers enhanced motor switching for higher-efficiency motors. The 440 V AC 60 Hz coil means the control voltage must be exactly 440 V AC at 60 Hz; a 50 Hz coil will not pull in reliably, and a 24 VDC coil requires a different order code. The 1 NC auxiliary contact provides one normally-closed feedback or interlock signal without adding a side-mount block. Mechanical robustness is specified for vibration (3 Gn closed, 1.5 Gn open) and shock (10 Gn closed, 7 Gn open), which covers most industrial panel environments including near punch presses or conveyors.

Frequently asked questions

What replaces the LC1E1201R6?

There is no official direct successor order code listed for this part. For a form-fit-function replacement, you would need to evaluate current Easy TeSys or TeSys Deca contactors with matching pole count, coil voltage, and auxiliary configuration.

What are the key ratings of the LC1E1201R6?

It is a 3-pole contactor rated 12 A in AC-3/AC-3e at ≤440 V, with a 440 V AC 60 Hz coil and one NC auxiliary contact. It also carries an AC-1 resistive rating and meets EN/IEC 60947-4-1.

What compliance documentation is available for the LC1E1201R6?

The contactor complies with EN/IEC 60947-1, -4-1, -5-1, GB/T 14048.1/4/5, and the glow-wire test at 850 °C per IEC 60695-2-1. It has protective treatment TH (pollution degree 3) per IEC 60068-2-30.

MPN
LC1E1201R6