Skip to main content
Schneider Electric LC1E120F6 — Contactors

Schneider LC1E120F6 Easy TeSys Contactor, 120A AC-3, 110VAC

MPNLC1E120F6
Obsolete

Schneider Electric Easy TeSys Control, LC1E120F6, 3P(3NO) contactor, AC-3 ≤440V 120A, 110V AC coil 60Hz, DIN rail/plate mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1E120F6 — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationMotor control Resistive load
LC1E120F6 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-3 AC-3e AC-1
LC1E120F6 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1E120F6 — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (6 Gn for 11 ms) Shocks contactor closed (7 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068-2-30 test Db
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E120F6 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5
LC1E120F6 — Mechanical
ParameterValue
Width120 mm
Height158 mm
Depth132 mm

Product details

The Schneider Electric LC1E120F6 is a 3-pole contactor from the Easy TeSys Control range, rated for AC-3 motor switching at 120 A up to 440 V, with a 110 V AC 60 Hz coil. It also carries AC-3e and AC-1 utilisation categories, meaning it handles both standard squirrel-cage motor starts and resistive loads. Built to EN/IEC 60947-4-1 (contactor standard) and 60947-5-1 (control circuit), with GB/T equivalents for Chinese-market compliance.

IP2X finger protection from the front, so it is safe for open-panel layouts where operators might reach in. Mechanical robustness rated to 3 Gn vibration closed and 7 Gn shock closed, so it holds in on mobile equipment or near heavy machinery.

If you need a drop-in replacement with the same footprint and coil voltage, a parametric cross-reference against the current Easy TeSys or TeSys Deca range is the practical next step — but that is a selection exercise, not a guaranteed pin-compatible swap. The existing unit's ratings (AC-3 120 A, 110 VAC coil, 3P) define the search criteria.

Frequently asked questions

What are the key ratings for this contactor?

AC-3 motor switching rated 120 A at ≤440 V, with a 110 V AC 60 Hz coil. Also rated for AC-1 resistive loads. Three poles, all normally open.

What standards does this contactor comply with?

It complies with EN/IEC 60947-1, 60947-4-1, and 60947-5-1, plus the Chinese GB/T equivalents 14048.1, 14048.4, and 14048.5. Fire resistance is 850 °C per IEC 60695-2-1.

How is the LC1E120F6 mounted?

It mounts on DIN rail or directly to a mounting plate. Dimensions are 120 mm wide, 158 mm high, 132 mm deep.

MPN