Skip to main content
Schneider Electric LC1E1210E5 — Contactors

Schneider Electric LC1E1210E5 Easy TeSys Contactor, 12A, 48V

MPNLC1E1210E5
Obsolete

Schneider Electric Easy TeSys Control contactor, LC1E1210E5, 3P(3NO), AC-3/AC-3e ≤440V, 12A, 48V AC 50Hz coil, 1NO auxiliary contact.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1E1210E5 — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationMotor control Resistive load
LC1E1210E5 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-3 AC-3e AC-1
LC1E1210E5 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1E1210E5 — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068-2-30 test Db
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E1210E5 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ
LC1E1210E5 — Mechanical
ParameterValue
Width45 mm
Height74 mm
Depth80 mm

Product details

The Schneider Electric LC1E1210E5 is a 3-pole contactor from the Easy TeSys Control range, rated for AC-3 and AC-3e duty up to 440 V at 12 A, with a 48 V AC 50 Hz coil and one normally open auxiliary contact. It is designed for motor control and resistive load switching, with a mechanical life backed by vibration and shock ratings — 1.5 Gn open, 3 Gn closed for vibrations, and 7 Gn open, 10 Gn closed for shocks.

The AC-3 rating of 12 A at ≤440 V is the motor-switching current — this contactor can handle a 3-phase induction motor up to roughly 5.5 kW at 400 V, depending on the exact load and duty cycle. The AC-3e rating extends the same current for enhanced motor switching per IEC 60947-4-1. The 48 V AC coil draws from a control transformer; at 50 Hz the hold-in is reliable down to about 85% of rated voltage. The 1.5 ms non-overlap time between NC and NO contacts ensures no momentary short across the power poles during transition.

The IP2X finger-safe front cover is standard for panel installation.

Certified to EN/IEC 60947-1, 60947-4-1, 60947-5-1, plus GB/T equivalents for the Chinese market. Operating altitude up to 3000 m without derating; ambient range -20 to 70 °C at the coil, -5 to 55 °C for operation.

Frequently asked questions

What are the key ratings for this contactor?

It is a 3-pole contactor rated AC-3/AC-3e at 12 A, ≤440 V, with a 48 V AC 50 Hz coil and one NO auxiliary contact. The non-overlap time between NC and NO is 1.5 ms on energisation and de-energisation.

What standards does the LC1E1210E5 comply with?

It complies with EN/IEC 60947-1, 60947-4-1, 60947-5-1, GB/T 14048.1, 14048.4, 14048.5, and portions of EN/IEC 60335-1 and 60335-2-40. Fire resistance is 850 °C per IEC 60695-2-1.

MPN
LC1E1210E5