Skip to main content
Schneider Electric LC1E160B6 — Contactors

Schneider LC1E160B6 Easy TeSys Contactor, 160A AC-3, 24V 60H

MPNLC1E160B6
Obsolete

Schneider Electric Easy TeSys Control LC1E, 3P(3NO) contactor, 160 A AC-3 / 100 A AC-3e at ≤440 V, 24 V AC 60 Hz coil, plate or DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1E160B6 — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationMotor control Resistive load
LC1E160B6 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-3 AC-3e AC-1
LC1E160B6 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1E160B6 — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (6 Gn for 11 ms) Shocks contactor closed (7 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068-2-30 test Db
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E160B6 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5
LC1E160B6 — Mechanical
ParameterValue
Width120 mm
Height158 mm
Depth132 mm

Product details

The Schneider Electric LC1E160B6 is a 3-pole contactor from the Easy TeSys Control range, rated 160 A in AC-3 duty (motor switching) and 100 A in AC-3e at up to 440 V. The 24 V AC 60 Hz coil pulls in the main poles; the non-overlap time of 1.5 ms on both energisation and de-energisation ensures the NC and NO contacts never close simultaneously during transition. It is designed for motor control and resistive loads, with utilisation categories AC-3, AC-3e, and AC-1 covering the common industrial switching curves. The TH protective treatment (pollution degree 3 per IEC 60068-2-30) means it handles humid, mildly corrosive environments without derating up to 3000 m altitude.

Mounts on either a plate or a DIN rail — the 120 mm width and 158 mm height fit standard panel layouts. Vibration tolerance of 3 Gn closed and shock survival at 7 Gn for 11 ms closed means it stays latched under moderate machine vibration.

Frequently asked questions

What are the key ratings for this contactor?

160 A in AC-3 duty at ≤440 V, 100 A in AC-3e, with a 24 V AC 60 Hz coil. It is a 3-pole (3NO) device from the Easy TeSys Control range.

How do I source this obsolete part?

It is sourced to order through independent channels against an RFQ. No standard stock or lead time is available.

What compliance standards does it meet?

It meets EN/IEC 60947-1, -4-1, -5-1 and GB/T 14048.1, -4, -5. Fire resistance is 850 °C per IEC 60695-2-1, and it carries TH protective treatment for pollution degree 3.

MPN
LC1E160B6