Schneider Electric LC1E160F7 — Contactors

Schneider Electric Easy TeSys LC1E160F7 Contactor, 160A AC-3

MPNLC1E160F7
Active

Schneider Electric Easy TeSys Control, LC1E160F7, 3P(3NO) contactor, AC-3/AC-3e ≤440 V, 160 A/100 A, 110 V AC coil, 50/60 Hz.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LC1E160F7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationMotor control Resistive load

Ratings & Performance

LC1E160F7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-3 AC-3e AC-1

Contacts & Poles

LC1E160F7 — Contacts & Poles
ParameterValue
Pole configuration3P

Environmental

LC1E160F7 — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (6 Gn for 11 ms) Shocks contactor closed (7 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068-2-30 test Db
Fire resistance850 °C conforming to IEC 60695-2-1

Approvals

LC1E160F7 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5

Mechanical

LC1E160F7 — Mechanical
ParameterValue
Width120 mm
Height158 mm
Depth132 mm

Product details

The LC1E160F7 is a 3-pole contactor from the Easy TeSys Control range, rated 160 A in AC-3 duty and 100 A in AC-3e duty up to 440 V. The AC-3 rating governs full-load motor switching; AC-3e adds margin for lightly inductive loads. The 110 V AC coil pulls in on 50/60 Hz control power. It's rated for 3000 m operating altitude without derating — that's useful if your gear sits at elevation, like a mining conveyor or a pumping station in the Rockies. That's enough for unheated enclosures in most climates.

The footprint is 120 mm wide by 158 mm tall by 132 mm deep, which fits a standard 4-module-wide slot on the rail. The IP2X finger protection means the front of the contactor is safe to touch, but it's not sealed against dust or moisture; keep it inside a panel. The non-overlap time between NC and NO contacts is guaranteed at 1.5 ms on both energisation and de-energisation — that prevents shoot-through in reversing or star-delta circuits.

Built and tested to EN/IEC 60947-1, 60947-4-1 (contactor/motor-starter), and 60947-5-1 (control-circuit device), plus the Chinese GB/T equivalents. The fire-resistance rating is 850 °C per IEC 60695-2-1 — the glow-wire test for flammability in a fault condition. Protective treatment is TH (pollution degree 3) per IEC 60068-2-30, meaning it withstands humid, tropical environments inside a panel.

Frequently asked questions

What are the key ratings I need to verify for fit?

The headline numbers are 160 A in AC-3 motor duty and 100 A in AC-3e duty, both at 440 V maximum, with a 110 V AC 50/60 Hz coil. The contactor is 3-pole, 3 normally-open main contacts.

MPN
LC1E160F7