Skip to main content
Schneider Electric LC1E18008B7IN — Contactors

Schneider LC1E18008B7IN Easy TeSys Contactor, 4P, 40A AC-1,

MPNLC1E18008B7IN
Obsolete

Schneider Electric Easy TeSys Control, LC1E18008B7IN, 4-pole contactor, 40 A AC-1 at ≤415 V, 24 V coil, DIN rail mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LC1E18008B7IN — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationResistive load

Ratings & Performance

LC1E18008B7IN — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-1

Contacts & Poles

LC1E18008B7IN — Contacts & Poles
ParameterValue
Pole configuration4P

Environmental

LC1E18008B7IN — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068
Fire resistance850 °C conforming to IEC 60695-2-1

Approvals

LC1E18008B7IN — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5

Mechanical

LC1E18008B7IN — Mechanical
ParameterValue
Width45 mm
Height74 mm
Depth80 mm

Product details

The LC1E18008B7IN is a 4-pole contactor from Schneider Electric's Easy TeSys Control range, configured with 2 normally-open and 2 normally-closed power poles (4P). It's rated for 40 A in AC-1 utilisation category, meaning it's designed for resistive loads — think heating elements, lighting banks, or other non-inductive circuits — up to 415 V. The coil pulls in at 24 V. Let me show you why that AC-1 rating matters: if you try to switch a motor (AC-3 duty) at 40 A, the contactor's arc-chamber isn't sized for the inductive kick, so keep this part on resistive or lightly inductive duty only.

The contactor carries approvals to EN/IEC 60947-1, 60947-4-1, and 60947-5-1, plus the Chinese GB/T equivalents — that covers the main international and Chinese industrial control standards.

Frequently asked questions

What are the key ratings for this contactor?

It's a 4-pole contactor (2NO+2NC) rated 40 A in AC-1 utilisation category at ≤415 V, with a 24 V coil. The AC-1 rating means it's intended for resistive loads, not motor starting.

What compliance documentation is available for this part?

The contactor is certified to EN/IEC 60947-1, 60947-4-1, and 60947-5-1, plus GB/T 14048 equivalents. It also meets 850 °C glow-wire fire resistance per IEC 60695-2-1 and TH protective treatment for pollution degree 3.

MPN
LC1E18008B7IN