Schneider Electric LC1E18008F7IN — Contactors

Schneider Electric LC1E18008F7IN Easy TeSys Contactor, 60A A

MPNLC1E18008F7IN
Active

Schneider Electric Easy TeSys Control contactor, LC1E18008F7IN, 4P (2NO+2NC), 60 A AC-1 up to 415 V, coil 110 V AC 50/60 Hz.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LC1E18008F7IN — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationResistive load

Ratings & Performance

LC1E18008F7IN — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-1

Contacts & Poles

LC1E18008F7IN — Contacts & Poles
ParameterValue
Pole configuration4P

Environmental

LC1E18008F7IN — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068
Fire resistance850 °C conforming to IEC 60695-2-1

Approvals

LC1E18008F7IN — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5

Mechanical

LC1E18008F7IN — Mechanical
ParameterValue
Width45 mm
Height74 mm
Depth80 mm

Product details

The Schneider Electric LC1E18008F7IN is an Easy TeSys Control contactor — a 4-pole (2NO + 2NC) unit rated for 60 A in AC-1 utilisation category up to 415 V, with a 110 V AC 50/60 Hz coil. For motor or inductive loads you'd need the AC-3 rating, which is lower — this part is built for straightforward on/off of resistive circuits.

IP2X means finger-safe from the front, but it's not sealed; keep it inside an enclosure, not out in the weather. Rated for operation at altitudes up to 3000 m and ambient temps from -5 °C to 55 °C, with storage down to -60 °C. That covers most control cabinets in heated plants or even unheated warehouses, as long as condensation isn't an issue.

That covers the main industrial control gear standards for contactors.

Non-overlap timing — a detail that matters for safety circuits

That means the normally-closed and normally-open sets never close at the same instant — important if you're using the NC as a feedback mirror in a safety circuit or a mechanical interlock.

Frequently asked questions

What are the key ratings of this contactor?

It is a 4-pole (2NO+2NC) contactor rated 60 A AC-1 (resistive load) up to 415 V, with a 110 V AC 50/60 Hz coil. It mounts on DIN rail, has IP2X protection, and operates from -5 °C to 55 °C.

What standards does it comply with?

It complies with EN/IEC 60947-1, -4-1, -5-1 and the Chinese GB/T 14048.1.4.5. It also meets 850 °C glow-wire test per IEC 60695-2-1 and TH pollution degree 3 protection.