Skip to main content
Schneider Electric LC1E18008M7IN — Contactors

Schneider Electric LC1E18008M7IN Easy TeSys Contactor, 4P, 8

MPNLC1E18008M7IN
Active

Schneider Electric Easy TeSys Control contactor, 4P (2 NO + 2 NC), AC-1 resistive load rated 80 A at ≤ 415 V, 220 V AC coil, DIN rail / plate mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LC1E18008M7IN — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationResistive load

Ratings & Performance

LC1E18008M7IN — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-1

Contacts & Poles

LC1E18008M7IN — Contacts & Poles
ParameterValue
Pole configuration4P

Environmental

LC1E18008M7IN — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068
Fire resistance850 °C conforming to IEC 60695-2-1

Approvals

LC1E18008M7IN — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5

Mechanical

LC1E18008M7IN — Mechanical
ParameterValue
Width45 mm
Height74 mm
Depth80 mm

Product details

The Schneider Electric LC1E18008M7IN is an Easy TeSys Control contactor with a 4-pole configuration (2 NO + 2 NC). It's rated for AC-1 utilisation category, meaning it's designed for resistive loads — think heaters, lighting banks, or transformer primaries — up to 80 A at ≤ 415 V. The coil pulls 220 V AC.

Mounts on DIN rail or a backplate — the evidence lists both as supported. Depth is 80 mm, height 74 mm. That's compact enough for a shallow enclosure but check gland-plate clearance if you're running cables behind the rail. IP2X protection means finger-safe from the front but not sealed — no washdown duty. This is a panel-interior part, not a field-mounted one.

Safety and switching characteristics

That's a deliberate mechanical guarantee that the NC pole breaks before the NO pole makes — critical for interlocking circuits where you must avoid a momentary short across the load. If you're wiring a reversing starter or a safety isolation chain, that 1.5 ms window is your design margin. Mechanical robustness specs: the contactor holds closed under 3 Gn vibration (5–300 Hz) and open under 1.5 Gn. Shock survival is 10 Gn closed, 7 Gn open. That's standard for industrial panel gear — fine for most conveyor and pump stations, but if it's going on a mobile platform or near a stamping press, verify against your specific shock profile.

Certified to EN/IEC 60947-1 (general rules), EN/IEC 60947-4-1 (contactors and motor-starters), and EN/IEC 60947-5-1 (control-circuit devices). Also meets GB/T 14048 equivalents for the Chinese market. Fire resistance is 850 °C per IEC 60695-2-1. Operating altitude is rated to 3000 m without derating — useful for high-altitude installations.

Frequently asked questions

What are the key ratings for this contactor?

It's a 4-pole (2 NO + 2 NC) contactor rated AC-1 at 80 A with a coil voltage of 220 V AC. The operational voltage on the power circuit is ≤ 415 V. It's designed for resistive loads per the AC-1 utilisation category.

MPN