Schneider Electric LC1E1801B6 — Contactors

Schneider LC1E1801B6 Easy TeSys Contactor, 18A, 24V AC, 3P,

MPNLC1E1801B6
Obsolete

Schneider Electric Easy TeSys Control contactor, LC1E1801B6, 3P (3NO), AC-3/AC-3e ≤440 V 18 A, 24 V AC 60 Hz coil, 1 NC auxiliary contact, obsolete.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1E1801B6 — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationMotor control Resistive load
LC1E1801B6 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-3 AC-3e AC-1
LC1E1801B6 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1E1801B6 — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068-2-30 test Db
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E1801B6 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ
LC1E1801B6 — Mechanical
ParameterValue
Width45 mm
Height74 mm
Depth80 mm

Product details

The LC1E1801B6 is a 3-pole contactor from Schneider Electric's Easy TeSys Control range, rated 18 A in AC-3/AC-3e duty at ≤440 V. The coil is 24 V AC, 60 Hz only, and it carries one normally closed auxiliary contact. This part is now obsolete per the manufacturer.

AC-3e is a more recent sub-category for high-efficiency motors; the contactor meets both. AC-1 (resistive) rating is higher but not the limiting spec for motor duty. The 24 V AC coil draws from a control transformer, not a DC supply — if your panel runs 24 VDC, this coil won't hold in. Mounts on DIN rail or plate. IP2X finger protection is typical for enclosed contactors — fine inside a panel, not for open mounting. Complies with EN/IEC 60947-4-1 (contactor standard), EN/IEC 60947-5-1 (auxiliary contact standard), and GB/T equivalents.

Sourcing reality — obsolete part

Schneider lists this contactor as obsolete. We can quote against an RFQ — the supply posture is quoted-to-order, not off-the-shelf. Confirm the coil voltage (24 V AC 60 Hz) and the auxiliary contact configuration (1 NC) before substituting; a different coil voltage or contact arrangement won't drop in without rewiring.

Frequently asked questions

What are the key ratings for this contactor?

Rated 18 A in AC-3/AC-3e motor duty at ≤440 V, with a 24 V AC 60 Hz coil and one NC auxiliary contact. The utilisation categories are AC-3, AC-3e, and AC-1.

What is the physical size and mounting?

Width 45 mm, height 74 mm, depth 80 mm. Mounts on DIN rail or plate.

MPN
LC1E1801B6