LC1E1801F5 — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationMotor control Resistive load
LC1E1801F5 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-3 AC-3e AC-1
LC1E1801F5 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1E1801F5 — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068-2-30 test Db
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E1801F5 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ
LC1E1801F5 — Mechanical
ParameterValue
Width45 mm
Height74 mm
Depth80 mm

Product details

It carries an AC-3 utilisation category rating of 18 A at up to 440 V, meaning it handles the high inrush of a standard induction motor during start and the lower running current without derating. The 110 V AC 50 Hz coil pulls in reliably across the operating temperature band (-5 to 55 °C operation, -20 to 70 °C at coil rated voltage).

The contactor is certified to EN/IEC 60947-1, -4-1, and -5-1, plus the Chinese GB/T equivalents — covering the main product standard for contactors and motor-starters. It also passes the glow-wire test at 850 °C per IEC 60695-2-1, and the TH protective treatment (pollution degree 3, per IEC 60068-2-30) means it withstands damp-heat cycling typical in non-conditioned industrial enclosures.

Mounts on DIN rail or directly to a plate — the 45 mm width and 80 mm depth fit standard 45 mm DIN-rail spacing, leaving room for side-by-side grouping with other Easy TeSys control gear. IP2X finger protection on the front means it's safe for open-panel wiring as long as the enclosure restricts tool access.

Frequently asked questions

What are the key ratings for this contactor?

AC-3 motor rating: 18 A at ≤440 V. Coil: 110 V AC, 50 Hz. One NC auxiliary contact. Operating temperature: -5 to 55 °C. Altitude: 3000 m without derating.

What compliance documentation does Schneider provide for LC1E1801F5?

The contactor is certified to EN/IEC 60947-1, -4-1, -5-1 and the Chinese GB/T 14048 series. It also meets the glow-wire test at 850 °C (IEC 60695-2-1) and TH pollution degree 3 (IEC 60068-2-30).

MPN