Skip to main content
Schneider Electric LC1E1801M5 — Contactors

Schneider LC1E1801M5 Easy TeSys Contactor, 18A AC-3, 220V AC

MPNLC1E1801M5
Active

Schneider Electric Easy TeSys Control LC1E1801M5, 3-pole contactor, 18 A AC-3 at ≤ 440 V, 220 V AC coil, DIN rail mount.

$16.83Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1E1801M5 — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationMotor control Resistive load
LC1E1801M5 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-3 AC-3e AC-1
LC1E1801M5 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1E1801M5 — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068-2-30 test Db
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E1801M5 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ
LC1E1801M5 — Mechanical
ParameterValue
Width45 mm
Height74 mm
Depth80 mm

Product details

The LC1E1801M5: AC-3 is the utilisation category for squirrel-cage motor starting: the 18 A rating means it handles a 3-phase motor drawing up to 18 A during running, with the inrush on make handled by the contactor's design. The same part also carries an AC-1 rating for resistive loads, though the evidence does not give the numeric value for that curve.

IP2X finger protection is built in, so it does not require an additional cover in a standard IP2X enclosure. The non-overlap time of 1.5 ms between NC and NO contacts on both energisation and de-energisation is a detail worth noting for safety circuits: it guarantees that the NC break before the NO make, preventing a momentary short across the coil circuit in reversing or interlocking applications.

Environmental and compliance envelope

The TH protective treatment per IEC 60068-2-30 means it is tested for damp heat — suitable for unheated warehouses or coastal plant rooms without condensation control. Operating altitude goes to 3000 m without derating, which covers most installations outside high-mountain sites.

Frequently asked questions

What are its key ratings for motor control?

The contactor is rated 18 A in AC-3 duty at up to 440 V, with a 220 V AC coil. It is a 3-pole device (3 NO main contacts).

What standards does it comply with?

It complies with EN/IEC 60947-1, 60947-4-1, 60947-5-1, and the corresponding GB/T standards. It also meets the glow-wire test at 850 °C per IEC 60695-2-1.

How is it mounted?

It mounts on a plate or DIN rail. The width is 45 mm, depth 80 mm, height 74 mm.

MPN