Schneider Electric LC1E1801Q7 — Contactors

Schneider LC1E1801Q7 Easy TeSys Contactor, 18A AC-3, 380VAC

MPNLC1E1801Q7
Active

Schneider Electric Easy TeSys Control, LC1E1801Q7, 3P contactor, 18 A AC-3 at ≤440 V, 380 V AC 50/60 Hz coil, 1 NC auxiliary contact.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LC1E1801Q7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationMotor control Resistive load

Ratings & Performance

LC1E1801Q7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-3 AC-3e AC-1

Contacts & Poles

LC1E1801Q7 — Contacts & Poles
ParameterValue
Pole configuration3P

Environmental

LC1E1801Q7 — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068-2-30 test Db
Fire resistance850 °C conforming to IEC 60695-2-1

Approvals

LC1E1801Q7 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ

Mechanical

LC1E1801Q7 — Mechanical
ParameterValue
Width45 mm
Height74 mm
Depth80 mm

Product details

The LC1E1801Q7 is a 3-pole contactor from Schneider Electric's Easy TeSys Control range, rated 18 A in AC-3 utilisation category at ≤440 V with a 380 V AC 50/60 Hz coil and one NC auxiliary contact. AC-3 is the standard duty for starting and stopping squirrel-cage induction motors under full load — so the 18 A figure is the motor current it handles, not a resistive-heater current. This contactor carries a full suite of international approvals: EN/IEC 60947-1, -4-1, and -5-1 for low-voltage switchgear, plus GB/T equivalents for the Chinese market, and EN/IEC 60335-1 Clause 30.2 for glow-wire resistance in household appliances. Fire resistance is tested to 850 °C per IEC 60695-2-1. It's TH-treated for pollution degree 3 environments (condensation-prone panels) per IEC 60068-2-30.

Operating altitude is 3000 m without derating — above that, the air's lower dielectric strength and cooling capacity need a correction factor. The non-overlap time between NC and NO contacts is guaranteed at 1.5 ms on both energisation and de-energisation. This matters in reversing or star-delta starters where you need a dead time between contactors to prevent phase-to-phase shorts.

Frequently asked questions

What is the AC-3 rating and why does it matter?

The AC-3 rating of 18 A at ≤440 V is the contactor's rated operational current for motor starting and stopping under full load. This is the figure that governs fit for most induction-motor applications — not the AC-1 resistive rating.

What standards does this contactor comply with?

It complies with EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, GB/T 14048.1, GB/T 14048.4, GB/T 14048.5, and EN/IEC 60335-1 Clause 30.2 with EN/IEC 60335-2-40 Annex JJ. Fire resistance is 850 °C per IEC 60695-2-1.

What is the mounting method?

Mounts on a DIN rail or directly to a mounting plate. Width is 45 mm, depth 80 mm, height 74 mm.

MPN
LC1E1801Q7