Schneider Electric LC1E1810B6 — Contactors

Schneider LC1E1810B6 Easy TeSys Contactor, 18A, 24V AC, Obso

MPNLC1E1810B6
Obsolete

Schneider Electric Easy TeSys Control LC1E1810B6, 3-pole contactor, 18 A AC-3/AC-3e at ≤440 V, 24 V AC 60 Hz coil, 1 NO auxiliary contact, obsolete.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1E1810B6 — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationMotor control Resistive load
LC1E1810B6 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-3 AC-3e AC-1
LC1E1810B6 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1E1810B6 — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068-2-30 test Db
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E1810B6 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ
LC1E1810B6 — Mechanical
ParameterValue
Width45 mm
Height74 mm
Depth80 mm

Product details

The Schneider Electric LC1E1810B6 is a 3-pole contactor from the Easy TeSys Control range, rated 18 A in AC-3 / AC-3e utilisation category at ≤440 V — meaning it switches standard three-phase squirrel-cage motors up to that current during starting and stopping, where the load current during acceleration is typically 5–7× the rated full-load current. The 24 V AC 60 Hz coil draws its control power from a dedicated transformer or control circuit; the 1 NO auxiliary contact provides a feedback or interlock signal without an add-on block. Rated operational voltage is listed for the power circuit; the control circuit is isolated.

The 18 A AC-3 rating, 24 V AC 60 Hz coil, 1 NO auxiliary, and DIN-rail footprint must be matched in a substitute.

Standards and compliance — what the approvals cover

It also complies with EN/IEC 60335-1 Clause 30.2 and EN/IEC 60335-2-40 Annex JJ for glow-wire and fire-resistance requirements — relevant if the contactor is used inside a household or commercial appliance. Protective treatment is TH (tropicalised, pollution degree 3) per IEC 60068-2-30, meaning it withstands high humidity and cyclic condensation — suitable for non-condensing environments in warm climates.

Environmental limits — where it can run

Permissible ambient air temperature around the device is -20 to 70 °C at the coil rated voltage (Uc), with storage from -60 to 80 °C, and operation from -5 to 55 °C. The narrower operating range (-5 to 55 °C) is the one that governs real panel conditions — the wider storage range simply means the part can survive shipping and warehouse extremes without damage. Mechanical robustness is specified at 1.5 Gn vibration (5–300 Hz) with contacts closed, and 10 Gn shock for 11 ms with contacts closed.

Frequently asked questions

What are the key ratings for fit?

18 A in AC-3 / AC-3e at ≤440 V, 24 V AC 60 Hz coil, 1 NO auxiliary contact, 3-pole, DIN-rail or plate mount, 45 mm width. Standards: EN/IEC 60947-4-1 and -5-1.

How do I source this obsolete part?

Through surplus or broker inventory. We can quote it against an RFQ, but availability is limited and no factory lead time applies.