Schneider Electric LC1E1810F6 Easy TeSys Contactor, 18A AC-3

MPNLC1E1810F6
Obsolete

Schneider Electric Easy TeSys Control, LC1E1810F6, 3P contactor, AC-3/AC-3e 18 A, 110 V AC coil 60 Hz, 1 NO auxiliary contact.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1E1810F6 — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationMotor control Resistive load
LC1E1810F6 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-3 AC-3e AC-1
LC1E1810F6 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1E1810F6 — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068-2-30 test Db
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E1810F6 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ
LC1E1810F6 — Mechanical
ParameterValue
Width45 mm
Height74 mm
Depth80 mm

Product details

It carries an AC-3 utilisation category rating of 18 A at up to 440 V, meaning it's sized for switching three-phase induction motors on and off under load — the standard duty cycle for conveyor drives, pumps, and compressors. The 110 V AC coil at 60 Hz matches North American control voltage common in older panels and retrofit work.

The AC-1 rating covers resistive loads like heaters, where the switching current is lower due to no inrush. The 110 V AC coil draws its control power from a separate circuit — verify the control transformer is sized for the coil inrush if you're replacing a different coil voltage variant. The contactor carries a 1.5 ms non-overlap time between NC and NO contacts, which matters if you're using the auxiliary for interlocking — it guarantees the NC opens before the NO closes on energisation, and vice versa on de-energisation.

TH protective treatment per IEC 60068-2-30 means it's tested for damp heat, so condensation in an unheated enclosure won't cause early failure.

Certified to EN/IEC 60947-1 (general rules), 60947-4-1 (contactors and motor-starters), and 60947-5-1 (control-circuit devices). Also meets GB/T equivalents for the Chinese market and EN/IEC 60335-1 Clause 30.2 for glow-wire resistance in household appliances.

Frequently asked questions

What are the key ratings for the LC1E1810F6?

It is a 3-pole contactor rated 18 A in AC-3 (motor switching) at up to 440 V, with a 110 V AC 60 Hz coil and one normally open auxiliary contact. It also carries AC-1 and AC-3e utilisation categories.

What standards does the LC1E1810F6 comply with?

It complies with EN/IEC 60947-1, 60947-4-1, 60947-5-1, GB/T 14048.1, 14048.4, 14048.5, and EN/IEC 60335-1 Clause 30.2. Fire resistance tested at 850 °C per IEC 60695-2-1.

How is the LC1E1810F6 mounted?

It mounts on a DIN rail or plate. Dimensions are 45 mm wide, 74 mm high, 80 mm deep.