Skip to main content
Schneider Electric LC1E1810M6 — Contactors

Schneider LC1E1810M6 Easy TeSys Contactor, 18A AC-3, 220VAC

MPNLC1E1810M6
Active

Schneider Electric Easy TeSys Control, contactor, LC1E1810M6, 3P(3NO), AC-3/AC-3e ≤440V, 18A, 220V AC coil 60Hz, 1NO auxiliary, DIN rail/plate mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1E1810M6 — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationMotor control Resistive load
LC1E1810M6 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-3 AC-3e AC-1
LC1E1810M6 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1E1810M6 — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068-2-30 test Db
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E1810M6 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ
LC1E1810M6 — Mechanical
ParameterValue
Width45 mm
Height74 mm
Depth80 mm

Product details

Where it goes and how it fits

The 45 mm width fits into a standard control panel.

Real-world deployment notes

Rated for operation from -5 °C to 55 °C ambient, with storage from -60 °C to 80 °C — fine for most indoor industrial environments, but if this lives in an unheated warehouse in a cold climate, the -5 °C lower operating limit matters; the contactor won't pull in reliably below that. It derates above 3000 m altitude, so at a high-altitude mine or mountain site, you need to check the thermal curve. The non-overlap time of 1.5 ms between NC and NO contacts is built in — that's a safety feature for interlocking, ensuring the NC opens before the NO closes on energisation and vice versa on de-energisation. That's good for reversing starters or bypass circuits where you can't have both sets closed simultaneously.

Frequently asked questions

What standards does it comply with?

It meets EN/IEC 60947-1, EN/IEC 60947-4-1 (contactor standard for motor starters), EN/IEC 60947-5-1 (control circuit devices), plus the Chinese GB/T equivalents. It also passes the 850 °C glow-wire test per IEC 60695-2-1 for fire resistance.

MPN
LC1E1810M6