The Schneider Electric LC1E1810M7 is a 3-pole EasyPact TVS contactor from the Easy TeSys Control range, rated 18 A in AC-3 duty at ≤ 440 V with a 220 V AC coil. It handles motor switching and resistive loads, and the 18 A AC-3 rating means it can start and stop a 3-phase motor drawing up to that current under full-load conditions — the rating that governs real-world motor control, not the higher AC-1 resistive figure.

Schneider Electric LC1E1810M7 EasyPact TVS Contactor, 18 A A
MPNLC1E1810M7
Active
Schneider Electric EasyPact TVS contactor, 3P (3 NO), AC-3 ≤ 440 V 18 A, 220 V AC coil, DIN-rail mount, IP2X.
$23.36Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026
Specifications
| Parameter | Value |
|---|---|
| Product / component type | Contactor |
| Series / range | Easy TeSys |
| Application | Motor control Resistive load |
| Parameter | Value |
|---|---|
| Rated operational voltage (Ue) | Power circuit: 10 MOhm for control circuit |
| Utilisation category | AC-3 AC-3e AC-1 |
| Parameter | Value |
|---|---|
| Pole configuration | 3P |
| Parameter | Value |
|---|---|
| IP degree of protection | IP2X conforming to IEC 60529 |
| Operating altitude | 3000 m without derating |
| Mechanical robustness | Vibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (7 Gn for 11 ms) Shocks contactor closed (10 Gn for 11 ms) |
| Protective treatment / pollution degree | TH (pollution degree 3) conforming to IEC 60068-2-30 test Db |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
| Parameter | Value |
|---|---|
| Standards | EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ |
| Parameter | Value |
|---|---|
| Width | 45 mm |
| Height | 74 mm |
| Depth | 80 mm |
Product details
Frequently asked questions
What are the key ratings for the LC1E1810M7?
It is a 3-pole contactor rated 18 A in AC-3 duty at ≤ 440 V, with a 220 V AC coil. It also carries AC-3e and AC-1 utilisation categories.
What standards does the LC1E1810M7 comply with?
It complies with EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, GB/T 14048.1, GB/T 14048.4, GB/T 14048.5, and EN/IEC 60335-1 Clause 30.2 and EN/IEC 60335-2-40 Annex JJ.
How is the LC1E1810M7 mounted?
It mounts on a DIN rail or plate, with an IP2X degree of protection.
MPN
LC1E1810M7