Schneider Electric LC1E25008M5WBIN — Contactors

Schneider Electric LC1E25008M5WBIN Easy TeSys Contactor, 50

MPNLC1E25008M5WBIN
Active

Schneider Electric Easy TeSys Control, contactor LC1E25008M5WBIN, 4 poles, 50 A AC-1, 220 V AC 50 Hz coil, screw clamp terminals, DIN rail mounting.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1E25008M5WBIN — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationResistive load
LC1E25008M5WBIN — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: <= 690 V AC 50/60 Hz
Utilisation categoryAC-1
LC1E25008M5WBIN — Contacts & Poles
ParameterValue
Pole configuration4P
LC1E25008M5WBIN — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
Operating altitude3000 m
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor closed (10 Gn for 11 ms) Shocks contactor open (6 Gn for 11 ms)
Protective treatment / pollution degreeTH conforming to IEC 60068
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E25008M5WBIN — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5
LC1E25008M5WBIN — Mechanical
ParameterValue
Width56 mm
Height84 mm
Depth93 mm

Product details

The Schneider Electric LC1E25008M5WBIN is a 4-pole contactor from the Easy TeSys Control range, rated for 50 A at ≤415 V AC in AC-1 utilisation category — meaning it's sized for resistive loads like heaters or lighting banks, not motor starting. The 220 V AC 50 Hz coil is wide-range, holding in at 0.7–1.25 Uc and dropping out at 0.3–0.6 Uc across -5 to 55 °C. Pole configuration is 2 NO + 2 NO (four poles total), with no auxiliary contact block fitted — you'll add one if you need feedback to a PLC or status indication on the panel door.

The headline 50 A AC-1 rating is the continuous resistive current at ≤40 °C — that's the number that governs your bus bar and cable sizing for a heater or transformer load. Don't confuse it with an AC-3 motor rating; this contactor is listed for resistive duty only per the utilisation category. Breaking capacity is 200 A at 440 V, making capacity 250 A at 440 V, so it handles inrush from cold resistive elements without welding. Mechanical durability of 10 million cycles and electrical durability of 350,000 cycles at AC-1 tell you it's built for frequent switching in a process line, not a once-a-day HVAC contactor.

Mounting, wiring, and panel integration

Power circuit terminals accept up to 10 mm² flexible with cable end, control circuit up to 4 mm². Tightening torque is 1.5 N·m on power, 1.2 N·m on control — use a torque screwdriver; overtightening strips the screw clamp on these smaller terminals.

Frequently asked questions

What are the key ratings I need to check for fit?

The two critical specs are the 50 A rated operational current in AC-1 (resistive load) at ≤415 V AC, and the 220 V AC 50 Hz control coil voltage. Pole configuration is 4 poles (2 NO + 2 NC).

What compliance standards does this contactor meet?

It complies with EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, and the Chinese GB/T equivalents GB/T 14048.1, GB/T 14048.4, GB/T 14048.5. Fire resistance is 850 °C per IEC 60695-2-1.

Does it include auxiliary contacts?

No, the contactor ships without auxiliary contacts — the pole contact composition is 2 NO + 2 NC on the main poles only. You will need to add a separate auxiliary contact block if you require feedback or status signaling.

MPN
LC1E25008M5WBIN