Skip to main content
Schneider Electric LC1E2501E7 — Contactors

Schneider LC1E2501E7 Easy TeSys Contactor, 25A AC-3, 48V AC

MPNLC1E2501E7
Active

Schneider Electric Easy TeSys Control LC1E2501E7, 3-pole contactor, 25 A AC-3 at ≤440 V, 48 V AC 50/60 Hz coil, 1 NC auxiliary contact.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1E2501E7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationMotor control Resistive load
LC1E2501E7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-3 AC-3e AC-1
LC1E2501E7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1E2501E7 — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor closed (10 Gn for 11 ms) Shocks contactor open (6 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068-2-30 test Db
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E2501E7 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ
LC1E2501E7 — Mechanical
ParameterValue
Width45 mm
Height74 mm
Depth85 mm

Product details

The Schneider Electric LC1E2501E7 is a 3-pole (3NO) contactor from the Easy TeSys Control range, rated 25 A in AC-3 utilisation category at ≤440 V with a 48 V AC 50/60 Hz coil and one NC auxiliary contact built in. AC-3 is the standard duty for squirrel-cage motor starting — switching loads under starting current and disconnecting only after the motor is off. So 25 A AC-3 means this contactor directly handles a motor drawing up to 25 A during start-up and run; for resistive loads (AC-1) it can carry more, but the AC-3 figure is the one that governs motor control fit.

IP2X finger protection on the contactor body itself; in a closed panel that's fine, but if it's mounted exposed, keep the front clear of accidental contact.

That covers most industrial control panels globally — no extra paperwork needed for CE-marked or CCC-marked installations.

Frequently asked questions

What is the closest pin-compatible alternative in the Easy TeSys family?

Within the same Easy TeSys Control range, the LC1E2501E7 has no direct pin-compatible sibling with a different coil voltage that shares the exact same footprint and aux contact configuration — the LC1E range is built around specific coil variants. If you need a different coil voltage, the corresponding LC1ExxxxEx part with the same 25 A AC-3 rating and 1NC aux will share the same mechanical dimensions and mounting pattern. Verify the coil code against the 48 V AC 50/60 Hz requirement before swapping.

What is the depth of the LC1E2501E7?

85 mm depth, with a width of 45 mm and height of 74 mm. That 85 mm is the body depth excluding any coil terminal projections — allow a few extra mm behind the panel for wiring clearance.

What compliance documentation does Schneider provide for this contactor?

The LC1E2501E7 carries EN/IEC 60947-1, -4-1, and -5-1 certifications, plus GB/T 14048 equivalents, and passes the 850 °C glow-wire test (IEC 60695-2-1) and TH damp-heat treatment. Standard Schneider declarations of conformity cover CE, CCC, and UKCA for this part. RoHS and REACH compliance are included in the standard documentation package — no separate request needed.

MPN
LC1E2501E7