Specifications

LC1E2510Q5 — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationMotor control Resistive load
LC1E2510Q5 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-3 AC-3e AC-1
LC1E2510Q5 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1E2510Q5 — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor closed (10 Gn for 11 ms) Shocks contactor open (6 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068-2-30 test Db
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E2510Q5 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ
LC1E2510Q5 — Mechanical
ParameterValue
Width45 mm
Height74 mm
Depth85 mm

Product details

The LC1E2510Q5: This is a three-pole contactor from the Easy TeSys Control range, rated 25 A in AC-3 duty (motor switching) at up to 440 V. That means it handles a 25 A motor load — typically a 7.5 kW induction motor on 400 V three-phase — without welding the main poles. The 380 V AC 50 Hz coil pulls in reliably down to about 0.85× nominal; the 1 NO auxiliary contact gives you one feedback or interlock signal. Fire resistance is tested to 850 °C per IEC 60695-2-1, and the TH protective treatment (pollution degree 3) means it survives humid, mildly corrosive panel environments — common in HVAC or light industrial lines.

Mounts on a DIN rail or plate — 45 mm wide, 74 mm tall, 85 mm deep. The IP2X finger-safe front cover is standard for panel-mount contactors. Ambient temperature range is -20 to 70 °C at the coil (Uc), with storage down to -60 °C. Vibration resistance is 3 Gn closed, 1.5 Gn open — adequate for most industrial panels but not for direct machine-mount on a vibrating press.

Frequently asked questions

What are the key ratings for this contactor?

Three-pole, 25 A in AC-3 (motor) duty at ≤440 V, 380 V AC 50 Hz coil, one normally open auxiliary contact. Also rated for AC-1 resistive loads.

What compliance standards does it meet?

Certified to EN/IEC 60947-1, -4-1, -5-1, and the Chinese GB/T 14048 series. Fire resistance tested to 850 °C per IEC 60695-2-1. TH treatment per IEC 60068-2-30 for humid environments.

How do I source this obsolete part?