Skip to main content
Schneider Electric LC1E32004N5WB — Contactors

Schneider Electric LC1E32004N5WB Easy TeSys Contactor, 45 A

MPNLC1E32004N5WB
Obsolete

Schneider Electric Easy TeSys LC1E32004N5WB contactor, 4-pole, 45 A AC-1, 415 V AC 50 Hz coil, IP20, DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1E32004N5WB — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationResistive load
LC1E32004N5WB — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: <= 690 V AC 50/60 Hz
Utilisation categoryAC-1
LC1E32004N5WB — Contacts & Poles
ParameterValue
Pole configuration4P
LC1E32004N5WB — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor closed (10 Gn for 11 ms) Shocks contactor open (6 Gn for 11 ms)
Protective treatment / pollution degreeTH conforming to IEC 60068-2-30 test Db
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E32004N5WB — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5
LC1E32004N5WB — Mechanical
ParameterValue
Width56 mm
Height84 mm
Depth93 mm

Product details

The Schneider Electric LC1E32004N5WB is a 4-pole contactor from the Easy TeSys Control range, rated for 45 A in AC-1 utilisation category at ≤440 V — that is the resistive-load rating, so it handles heaters, lighting banks, or transformer primaries at that current. The 415 V AC 50 Hz coil is a wide-range AC control circuit, meaning it pulls in reliably between 0.7 and 1.25 times rated voltage and drops out between 0.3 and 0.6 times rated. No auxiliary contacts are built in, so if you need feedback or a hold-in circuit, you will add a side-mount block.

The screw-clamp terminals accept up to 6 mm² on the power circuit and 4 mm² on the control circuit, with a tightening torque of 2.1 N·m for power and 1.2 N·m for control. That is enough for a 45 A resistive circuit using 4–6 mm² cable, but if you are paralleling conductors or using fine-stranded wire, verify the terminal range for your cable end. The TH protective treatment (conforming to IEC 60068-2-30) means it is tested for humid tropical conditions — useful if the panel sees condensation cycles.

Frequently asked questions

What are the key ratings I need to check for fit?

The headline rating is 45 A at ≤440 V in AC-1 (resistive load) with a 415 V AC 50 Hz coil. It has 4 NO poles, no auxiliary contacts, and a rated breaking capacity of 256 A at 440 V. The rated making capacity is 320 A at 440 V AC. These numbers govern whether it handles your load circuit and control voltage.

What compliance standards does it meet?

It conforms to EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, and the Chinese GB/T equivalents. The rated insulation voltage is 690 V per IEC 60947-4-1, and the fire resistance is 850 °C per IEC 60695-2-1.

MPN
LC1E32004N5WB