Skip to main content
Schneider Electric LC1E32008B7IN — Contactors

Schneider Electric LC1E32008B7IN Easy TeSys Contactor, 4P 16

MPNLC1E32008B7IN
Obsolete

Schneider Electric Easy TeSys contactor, 4P (2 NO + 2 NC), AC-1 utilisation category, ≤415 V 16 A, 24 V AC coil, DIN rail mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LC1E32008B7IN — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationResistive load

Ratings & Performance

LC1E32008B7IN — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-1

Contacts & Poles

LC1E32008B7IN — Contacts & Poles
ParameterValue
Pole configuration4P

Environmental

LC1E32008B7IN — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor closed (10 Gn for 11 ms) Shocks contactor open (6 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068
Fire resistance850 °C conforming to IEC 60695-2-1

Approvals

LC1E32008B7IN — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5

Mechanical

LC1E32008B7IN — Mechanical
ParameterValue
Width56 mm
Height64 mm
Depth93 mm

Product details

It is rated for AC-1 utilisation category at 16 A up to 415 V, with a 24 V AC coil. This means it is designed for resistive load switching — heaters, lighting banks, or transformer primaries — where inrush current is minimal and the load current stays close to steady-state. The AC-1 rating is the key fit parameter here: if your application involves motor starting (AC-3) or mixed loads, this contactor is not the right choice.

This part is marked as Obsolete by the manufacturer. If you are freezing a new design, look at the current Easy TeSys or TeSys Deca contactor families for a functional equivalent — but verify the coil voltage, pole configuration, and AC-1 rating match your load.

Compliant with EN/IEC 60947-1, EN/IEC 60947-4-1, and EN/IEC 60947-5-1, plus the Chinese GB/T equivalents. Operating altitude rated to 3000 m without derating.

Frequently asked questions

What is the closest alternative to LC1E32008B7IN?

There is no official successor order code listed. For a new design, look at the current Easy TeSys or TeSys Deca contactor families with the same pole count (4P, 2 NO + 2 NC), AC-1 rating of at least 16 A at 415 V, and a 24 V AC coil. Verify the mounting footprint and terminal compatibility before substituting.

What compliance documentation is available for this part?

The part is certified to EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, and the Chinese GB/T equivalents. Fire resistance is tested to 850 °C per IEC 60695-2-1. Protective treatment TH (pollution degree 3) per IEC 60068. Standard Schneider Electric declarations of conformity and material compliance (RoHS, REACH) should be available through their documentation portal.