Schneider Electric Easy TeSys Control, LC1E38004M5WBIN, 4-pole contactor, 50 A AC-1 at 415 V, 220 V AC 50 Hz coil, IP20, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1E38004M5WBIN — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationResistive load
LC1E38004M5WBIN — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: <= 690 V AC 50/60 Hz
Utilisation categoryAC-1
LC1E38004M5WBIN — Contacts & Poles
ParameterValue
Pole configuration4P
LC1E38004M5WBIN — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
Operating altitude3000 m
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor closed (10 Gn for 11 ms) Shocks contactor open (6 Gn for 11 ms)
Protective treatment / pollution degreeTH conforming to IEC 60068
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E38004M5WBIN — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5
LC1E38004M5WBIN — Mechanical
ParameterValue
Width56 mm
Height84 mm
Depth93 mm

Product details

Its headline rating is 50 A at up to 415 V AC — the current it can carry continuously in a resistive circuit without exceeding temperature limits. The four NO (normally-open) main poles close to make the load and open to break it, with an operating time of 12–22 ms on closing and 4–19 ms on opening. The coil is 220 V AC at 50 Hz, drawing 95 VA inrush at 20 °C.

The 50 A AC-1 rating is the key selection number — it tells you the contactor can handle resistive loads (heaters, ovens, lighting banks) at that current. AC-1 is the least stressful duty; for motor loads (AC-3) the same contactor would be derated.

The 56 mm width and 84 mm height fit standard panel layouts — plan for the 93 mm depth when the door clears. Connections are screw-clamp terminals: power circuit accepts up to 10 mm² flexible with cable end, control circuit up to 4 mm². Tightening torque is 2.1 N·m on the power side, 1.2 N·m on the control side.

Frequently asked questions

What are the key ratings I need to check for fit?

The headline rating is 50 A at 415 V AC under AC-1 utilisation category for resistive loads. The coil is 220 V AC 50 Hz. It has 4 NO main poles and no auxiliary contacts built in. Rated insulation voltage is 690 V. These are the numbers that govern fit for a BOM line.

What compliance standards does this contactor meet?

It complies with EN/IEC 60947-1, EN/IEC 60947-4-1, and EN/IEC 60947-5-1, plus the Chinese GB/T equivalents. Fire resistance is tested at 850 °C per IEC 60695-2-1. Protective treatment is TH conforming to IEC 60068 for tropical environments.