Schneider Electric Easy TeSys contactor, LC1E38004M7IN, 4P 4NO, AC-1 20A ≤415V, 220V AC coil, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1E38004M7IN — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationResistive load
LC1E38004M7IN — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-1
LC1E38004M7IN — Contacts & Poles
ParameterValue
Pole configuration4P
LC1E38004M7IN — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor closed (10 Gn for 11 ms) Shocks contactor open (6 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E38004M7IN — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5
LC1E38004M7IN — Mechanical
ParameterValue
Width56 mm
Height64 mm
Depth93 mm

Product details

The LC1E38004M7IN is a 4-pole (4 NO) Easy TeSys contactor from Schneider Electric, rated for AC-1 resistive loads at 20 A up to 415 V, with a 220 V AC coil. It's the straightforward choice for switching resistive loads like heaters or lighting banks in a control panel — no derating gymnastics for inductive kickback. That AC-1 rating means it's sized for resistive duty where inrush is minimal. If you're switching motor loads (AC-3), this isn't the contactor you want — the inductive break current would be lower. Stick to the spec: resistive loads only, up to 20 A continuous.

No special cutouts needed. IP2X finger protection on the contactor body means it's safe for open-panel mounting where incidental contact is possible, but it's not sealed against washdown. Keep it inside the enclosure.

Operates from -5 °C to 55 °C ambient, stores from -60 °C to 80 °C. Good for a heated plant floor or a cold warehouse — just don't try to switch it below -5 °C. Rated for altitudes up to 3000 m — no derating needed for most installations outside high-mountain sites.

Frequently asked questions

What is the closest alternative in the Easy TeSys family?

Within the same Easy TeSys range, the closest sibling would be a 4-pole contactor with a different coil voltage or a 3-pole variant if you don't need the fourth pole. The LC1E38004M7IN is the 4 NO, 20 A AC-1, 220 V AC coil version — any alternative would differ on coil voltage or pole count. No direct pin-compatible drop-in with different ratings exists in this family; you'd need to match the coil and pole configuration exactly.

What compliance documentation is available for this contactor?

It's certified to EN/IEC 60947-1, -4-1, and -5-1, plus GB/T 14048.1.4, and.5. Fire resistance per IEC 60695-2-1 at 850 °C. Protective treatment TH (pollution degree 3) per IEC 60068. RoHS and REACH declarations are standard for Schneider's Easy TeSys line — request those with your RFQ.