Skip to main content
Schneider Electric LC1E38008N5WBIN — Contactors

Schneider Electric Easy TeSys LC1E38008N5WBIN Contactor, 50

MPNLC1E38008N5WBIN
Obsolete

Schneider Electric Easy TeSys LC1E38008N5WBIN, 4-pole contactor, 50 A AC-1 rated operational current, 415 V AC 50 Hz control circuit, IP20, DIN rail or plate mount.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LC1E38008N5WBIN — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationResistive load

Ratings & Performance

LC1E38008N5WBIN — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: <= 690 V AC 50/60 Hz
Utilisation categoryAC-1

Contacts & Poles

LC1E38008N5WBIN — Contacts & Poles
ParameterValue
Pole configuration4P

Environmental

LC1E38008N5WBIN — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
Operating altitude3000 m
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor closed (10 Gn for 11 ms) Shocks contactor open (6 Gn for 11 ms)
Protective treatment / pollution degreeTH conforming to IEC 60068
Fire resistance850 °C conforming to IEC 60695-2-1

Approvals

LC1E38008N5WBIN — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5

Mechanical

LC1E38008N5WBIN — Mechanical
ParameterValue
Width56 mm
Height84 mm
Depth93 mm

Product details

What the 50 A AC-1 rating means for your panel

The LC1E38008N5WBIN is a 4-pole contactor from the Easy TeSys range, rated 50 A in AC-1 utilisation category at ≤ 415 V AC. AC-1 covers resistive loads — heaters, lighting banks, and non-inductive circuits where the current inrush is minimal. For motor duty (AC-3), you derate; this part is spec'd for resistive switching, not across-the-line motor starting. The 4-pole configuration gives 2 NO + 2 NC main poles, so you can switch a three-phase resistive load plus a neutral, or split the poles across two independent circuits.

Control circuit and coil

Pickup is guaranteed at 0.7 to 1.25 Uc; drop-out occurs between 0.3 and 0.6 Uc across -5 to 55 °C. Inrush power is 95 VA at 50 Hz, cos φ 0.75, at 20 °C. Heat dissipation from the control circuit runs 2 to 3 W. The operating time is 12 to 22 ms on closing, 4 to 19 ms on opening — fast enough for general switching but not for high-speed synchronisation.

Dimensions are 93 mm deep, 56 mm wide, 84 mm tall — a compact footprint for a 4-pole 50 A contactor. Power-circuit terminals accept 1 to 10 mm² solid or 1 to 6 mm² flexible with cable end; control-circuit terminals take 1 to 4 mm². Tightening torque is 2.1 N·m for power, 1.2 N·m for control.

The rated breaking capacity is 304 A at 440 V; the rated making capacity is 380 A at 440 V AC. Associated fuse recommendation is 63 A gG at ≤ 690 V, coordination type 1. Protective treatment is TH conforming to IEC 60068 for tropical environments.

Frequently asked questions

What are the key ratings for this contactor?

The key ratings are 50 A rated operational current in AC-1 at ≤ 415 V AC, 4-pole configuration with 2 NO + 2 NC, 415 V AC 50 Hz control coil, IP20 protection, and 350,000 electrical cycles in AC-1.

What is the mounting option and physical size?

The contactor mounts on DIN rail or directly to a backplate. Dimensions are 93 mm deep, 56 mm wide, and 84 mm tall.

What compliance documentation is available for this part?

The contactor is certified to EN/IEC 60947-1, -4-1, and -5-1, plus GB/T 14048.1.4, and.5. It carries TH protective treatment per IEC 60068 and fire resistance to 850 °C per IEC 60695-2-1. Specific RoHS, REACH, or UL documentation should be confirmed at the time of order against the RFQ.

MPN