Schneider LC1E38008Q7IN Easy TeSys Contactor, 4P, 60A AC-1

MPNLC1E38008Q7IN
Obsolete

Schneider Electric Easy TeSys Control, LC1E38008Q7IN, 4P (2NO+2NC) contactor, AC-1 rated 60A at ≤415V, 380V coil.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

LC1E38008Q7IN — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationResistive load

Ratings & Performance

LC1E38008Q7IN — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-1

Contacts & Poles

LC1E38008Q7IN — Contacts & Poles
ParameterValue
Pole configuration4P

Environmental

LC1E38008Q7IN — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor closed (10 Gn for 11 ms) Shocks contactor open (6 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068
Fire resistance850 °C conforming to IEC 60695-2-1

Approvals

LC1E38008Q7IN — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5

Mechanical

LC1E38008Q7IN — Mechanical
ParameterValue
Width56 mm
Height64 mm
Depth93 mm

Product details

Its headline rating is 60 A in AC-1 utilisation category at ≤415 V — that means it's sized for resistive loads like heaters or lighting banks, not motor starting. The 380 V coil suits standard European control voltages.

The closest active sibling is the LC1E38008Q7N (same coil, same 60 A AC-1 rating, same 4P layout) — verify pinout and mounting compatibility against your panel layout before committing the line.

What the ratings actually mean for fit

The AC-1 60 A rating is the continuous resistive current the main poles can carry without derating. That's the figure that governs thermal sizing in a panel — not the motor-breaking AC-3 rating this part doesn't carry. If your load is a resistive bank (heater, lighting, ballast), this contactor is correctly specified. For inductive or motor loads, you need an AC-3 or AC-4 rated device. The 2NO+2NC auxiliary configuration is built into the main poles — no separate aux block needed for basic signalling. The 380 V coil draws its rated inrush and hold power from the control transformer; verify the control circuit can supply the inrush without dropping below the dropout threshold.

Physical integration and environment

Dimensions are 56 mm wide, 64 mm high, 93 mm deep — a compact 4-pole footprint that fits standard 35 mm DIN rail or direct plate mounting. Rated for ambient operation -5 to 55 °C, storage -60 to 80 °C.

Frequently asked questions

What replaces the LC1E38008Q7IN?

No official successor order code is published. The closest active sibling is the LC1E38008Q7N — same coil voltage, same 60 A AC-1 rating, same 4P layout. Verify pinout and mounting compatibility before substituting.

What are the key ratings for this contactor?

4 poles configured 2NO+2NC, AC-1 utilisation category rated 60 A at ≤415 V, with a 380 V coil. It is designed for resistive loads, not motor starting.

What standards does the LC1E38008Q7IN comply with?

It complies with EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, and the Chinese GB/T 14048.1, GB/T 14048.4, GB/T 14048.5. Fire resistance is 850 °C per IEC 60695-2-1.