The LC1E3801BD is a 3-pole contactor from the Easy TeSys Control range, rated 38 A in AC-3 and AC-3e utilisation categories at ≤440 V, with a 24 V DC coil and one normally-closed auxiliary contact built in. AC-3 and AC-3e are the standard duty classes for squirrel-cage motor switching — making and breaking locked-rotor currents during start/stop cycles. The 38 A AC-3 rating means it handles motor loads up to roughly 18.5 kW at 400 V three-phase, depending on the specific motor full-load current. The 24 V DC coil is common in PLC-controlled panels and safety circuits where a low-voltage DC supply is available. The single NC auxiliary contact can be wired as a feedback signal to confirm the contactor has dropped out.
Schneider LC1E3801BD Easy TeSys Contactor, 38A AC-3, 24V DC
MPNLC1E3801BD
Active
Schneider Electric Easy TeSys Control, LC1E3801BD, 3P(3NO) contactor, AC-3/AC-3e 38 A at ≤440 V, 24 V DC coil, 1 NC auxiliary contact.
StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →Specifications
Identification
| Parameter | Value |
|---|---|
| Product / component type | Contactor |
| Series / range | Easy TeSys |
| Application | Motor control Resistive load |
Ratings & Performance
| Parameter | Value |
|---|---|
| Rated operational voltage (Ue) | Power circuit: 10 MOhm for signalling circuit |
| Utilisation category | AC-3 AC-3e AC-1 |
Contacts & Poles
| Parameter | Value |
|---|---|
| Pole configuration | 3P |
Environmental
| Parameter | Value |
|---|---|
| IP degree of protection | IP20 conforming to IEC 60529 |
| Operating altitude | 3000 m without derating |
| Mechanical robustness | Shocks contactor open (5 Gn for 11 ms) conforming to IEC 60068-2-7 Shocks contactor closed (10 Gn for 11 ms) conforming to IEC 60068-2-7 Vibrations contactor open (1.5 Gn, 5...300 Hz) conforming to IEC 60068-2-6 Vibrations contactor closed (3 Gn, 5...300 Hz) conforming to IEC 60068-2-6 |
| Protective treatment / pollution degree | TH conforming to IEC 60068-2-30 test Db |
| Fire resistance | 850 °C conforming to IEC 60695-2-1 |
Approvals
| Parameter | Value |
|---|---|
| Standards | EN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 |
Mechanical
| Parameter | Value |
|---|---|
| Width | 56 mm |
| Height | 85 mm |
| Depth | 99 mm |
Product details
Frequently asked questions
What are the key ratings for this contactor?
Three-pole, 38 A in AC-3/AC-3e at ≤440 V. Coil is 24 V DC. Includes one NC auxiliary contact. Mounts on DIN rail or plate. Operating temperature -5 °C to 55 °C.
What standards does this contactor comply with?
It meets EN/IEC 60947-1, 60947-4-1, and 60947-5-1, plus the Chinese GB/T 14048 series. Fire resistance is 850 °C per IEC 60695-2-1. Protective treatment is TH (tropical heat/humidity) per IEC 60068-2-30.
MPN