Skip to main content
Schneider Electric LC1E3801Q6 — Contactors

Schneider LC1E3801Q6 Easy TeSys Contactor, 38A AC-3, 380V 60

MPNLC1E3801Q6
Obsolete

Schneider Electric Easy TeSys Control LC1E, contactor, 3P(3NO), AC-3/AC-3e ≤440V, 38A, 380V AC coil 60Hz, 1NC auxiliary contact.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1E3801Q6 — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationMotor control Resistive load
LC1E3801Q6 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-3 AC-3e AC-1
LC1E3801Q6 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1E3801Q6 — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor closed (10 Gn for 11 ms) Shocks contactor open (6 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068-2-30 test Db
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E3801Q6 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ
LC1E3801Q6 — Mechanical
ParameterValue
Width56 mm
Height84 mm
Depth86 mm

Product details

It switches 38 A in AC-3 duty at up to 440 V, with a 380 V AC coil at 60 Hz and a single NC auxiliary contact built in. Rated utilisation categories AC-3, AC-3e, and AC-1 mean it handles motor start/stop, high-inrush motor loads, and resistive heating elements without derating down to the listed voltage.

IP2X finger-safe protection on the front, so it can sit in a standard enclosure without additional shrouding on the operator side.

Lifecycle reality

If a replacement is required for a design-in, the Easy TeSys range has been superseded by newer contactor families — verify coil voltage and auxiliary configuration against a current equivalent before committing the BOM line.

Mechanical robustness specs — 3 Gn vibration closed, 10 Gn shock closed — mean it stays latched through pump starts and conveyor impacts. The 850 °C fire resistance (IEC 60695-2-1) is the glow-wire test, relevant for appliance and HVAC applications covered by EN/IEC 60335. The wider storage window matters for spares kept in unheated warehouses.

Frequently asked questions

What compliance standards does the LC1E3801Q6 meet?

It complies with EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, GB/T 14048.1/4/5, and EN/IEC 60335-1 Clause 30.2 and 60335-2-40 Annex JJ for appliance use. Fire resistance is 850 °C per IEC 60695-2-1.

What is the physical size of this contactor?

Width 56 mm, height 84 mm, depth 86 mm. It mounts on a DIN rail or plate.

What coil voltage and frequency does it need?

380 V AC at 60 Hz. The coil draws power from that supply.

MPN