Skip to main content
Schneider Electric LC1E40004E7IN — Contactors

Schneider LC1E40004E7IN Easy TeSys Contactor, 4P, AC-1 72A,

MPNLC1E40004E7IN
Obsolete

Schneider Electric Easy TeSys Control, LC1E40004E7IN, 4P (4NO) contactor, AC-1 72 A at ≤415 V, 48 V coil, obsolete.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1E40004E7IN — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationResistive load
LC1E40004E7IN — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-1
LC1E40004E7IN — Contacts & Poles
ParameterValue
Pole configuration4P
LC1E40004E7IN — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (6 Gn for 11 ms) Shocks contactor closed (7 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E40004E7IN — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5
LC1E40004E7IN — Mechanical
ParameterValue
Width85 mm
Height127 mm
Depth110 mm

Product details

The Schneider Electric LC1E40004E7IN is a 4-pole (4NO) contactor from the Easy TeSys Control range, rated for resistive load switching in AC-1 duty at 72 A up to 415 V. The 48 V coil makes it a fit for control transformers or 48 VDC auxiliary buses common in older panel designs.

The AC-1 rating of 72 A is the key selection number — it governs switching resistive loads (heaters, lighting banks, non-inductive circuits) at that current level. The contactor is not rated for motor starting (AC-3) duty, so don't spec it for a pump or conveyor without checking the load type. The 48 V coil holds in at nominal voltage; standard EN/IEC 60947-4-1 governs the contactor's performance for motor-starter applications, while EN/IEC 60947-5-1 covers the control circuit side.

DIN-rail or plate mounting, 85 mm wide by 127 mm tall by 110 mm deep — fits a standard 4-pole contactor footprint. Altitude rated to 3000 m without derating.

Frequently asked questions

What compliance standards does the LC1E40004E7IN meet?

It complies with EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, and the Chinese GB/T equivalents. Fire resistance is tested to 850 °C per IEC 60695-2-1. The protective treatment meets TH (pollution degree 3) per IEC 60068.

MPN
LC1E40004E7IN