Schneider Electric LC1E40004N5WBIN — Contactors

Schneider LC1E40004N5WBIN Easy TeSys Contactor, 75 A AC-1, 4

MPNLC1E40004N5WBIN
Active

Schneider Electric Easy TeSys Control contactor, 4-pole, 4 NO, 75 A AC-1, 415 V AC 50 Hz coil, screw clamp terminals.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1E40004N5WBIN — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationResistive load
LC1E40004N5WBIN — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: <= 690 V AC 50/60 Hz
Utilisation categoryAC-1
LC1E40004N5WBIN — Contacts & Poles
ParameterValue
Pole configuration4P
LC1E40004N5WBIN — Environmental
ParameterValue
IP degree of protectionIP20 conforming to IEC 60529
Operating altitude3000 m
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (6 Gn for 11 ms) Shocks contactor closed (7 Gn for 11 ms)
Protective treatment / pollution degreeTH conforming to IEC 60068
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E40004N5WBIN — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5
LC1E40004N5WBIN — Mechanical
ParameterValue
Width85 mm
Height127 mm
Depth110 mm

Product details

Its headline rating is 75 A at up to 415 V AC (AC-1 duty), which means it handles the steady-state current of resistive heaters, ovens, or lighting banks without the inrush stress of motor starting. The coil is 415 V AC 50 Hz wide-range, with a 160 VA inrush at 20 °C and a 6...10 W heat dissipation in the control circuit — a figure to budget for in a crowded panel.

Mounts on plate or DIN rail, with dimensions 85 mm wide × 127 mm high × 110 mm deep — a compact footprint for a 75 A 4-pole block. Power-circuit screw terminals accept 2.5...25 mm² flexible with cable end (solid up to 25 mm²); control-circuit terminals take 1...4 mm². Tightening torque is 5 N.m on the power side, 1.2 N.m on the control side.

Frequently asked questions

What are the key ratings for this contactor?

Rated operational current is 75 A at ≤ 415 V AC in AC-1 (resistive load) category. The coil is 415 V AC 50 Hz wide-range. Breaking capacity is 320 A at 440 V; making capacity is 400 A at 440 V AC. Mechanical durability is 5 million cycles; electrical durability is 350,000 cycles in AC-1.

What compliance documentation does this contactor carry?

It conforms to EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, and the Chinese GB/T equivalents. Protective treatment is TH conforming to IEC 60068. IP20 protection per IEC 60529. Fire resistance at 850 °C per IEC 60695-2-1.

MPN