Schneider Electric Easy TeSys Control contactor, LC1E40004P7IN, 4P (4NO), AC-1 utilisation category, ≤415 V, 72 A, 230 V coil.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1E40004P7IN — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationResistive load
LC1E40004P7IN — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-1
LC1E40004P7IN — Contacts & Poles
ParameterValue
Pole configuration4P
LC1E40004P7IN — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (6 Gn for 11 ms) Shocks contactor closed (7 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E40004P7IN — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5
LC1E40004P7IN — Mechanical
ParameterValue
Width85 mm
Height127 mm
Depth110 mm

Product details

The Schneider LC1E40004P7IN is a 4-pole (4NO) contactor from the Easy TeSys Control range, rated for AC-1 resistive loads up to 72 A at ≤415 V with a 230 V coil. It's built to switch resistive heating elements, lighting banks, or similar loads where inrush is minimal — the AC-1 category means the current stays steady through make and break, so there's no motor-start stress on the contacts.

If your load is a resistive heater bank drawing 65 A, this contactor has headroom. But if the load is inductive (motors, transformers), the AC-3 or AC-4 rating would be lower — this part is not specified for those categories, so don't substitute it into a motor-starting circuit without checking the actual duty. Mechanical endurance is backed by vibration and shock ratings: 1.5 Gn open, 3 Gn closed across 5–300 Hz, and shock survival at 6 Gn open / 7 Gn closed for 11 ms. That's enough for most industrial panels mounted on a machine base — not for mobile equipment or high-vibration conveyors. The -20 to 70 °C at Uc figure covers the coil voltage range — if the panel gets below -5 °C during operation, the coil might not pull in reliably.

Frequently asked questions

What are the key ratings for the LC1E40004P7IN?

It's a 4-pole (4NO) contactor rated AC-1 at 72 A, ≤415 V, with a 230 V coil. It's designed for resistive loads, mounts on plate or DIN rail, and has IP2X finger protection.

What standards does the LC1E40004P7IN comply with?

It complies with EN/IEC 60947-1, -4-1, -5-1, and the Chinese GB/T 14048 series. Fire resistance is 850 °C per IEC 60695-2-1.

How do I source the LC1E40004P7IN if it's obsolete?

Since it's obsolete, we source it through surplus and broker networks against an RFQ. Submit a request with your quantity and target timeline, and we'll check availability.