Skip to main content
Schneider Electric LC1E40008E7IN — Contactors

Schneider LC1E40008E7IN Easy TeSys Contactor, 4P, 72A, AC-1,

MPNLC1E40008E7IN
Obsolete

Schneider Electric Easy TeSys Control contactor, LC1E40008E7IN, 4P (2NO+2NC), AC-1 ≤415V 72A, 48V coil, obsolete.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1E40008E7IN — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationResistive load
LC1E40008E7IN — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-1
LC1E40008E7IN — Contacts & Poles
ParameterValue
Pole configuration4P
LC1E40008E7IN — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (6 Gn for 11 ms) Shocks contactor closed (7 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E40008E7IN — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5
LC1E40008E7IN — Mechanical
ParameterValue
Width85 mm
Height127 mm
Depth110 mm

Product details

The Schneider Electric LC1E40008E7IN is an Easy TeSys Control contactor — a 4-pole (2NO+2NC) device rated for 72 A in AC-1 utilisation category at ≤415 V, with a 48 V coil. It's built to handle resistive loads in control panels, switching heater banks, lighting, or other non-inductive circuits where inrush is minimal. Operating altitude goes to 3000 m, and the ambient range is -20 to 70 °C at the coil, with storage from -60 to 80 °C. The part carries EN/IEC 60947-1, -4-1, and -5-1 plus the corresponding GB/T standards, along with 850 °C glow-wire fire resistance per IEC 60695-2-1.

Sourcing reality — obsolete

This part is now obsolete. No direct official successor is listed on the lifecycle record. For a line-down situation or BOM fill, your route is the surplus and broker channel — we source these against an RFQ. If you're designing a new panel or replacing this on a maintenance schedule, look at the current Easy TeSys range for a functionally equivalent 4-pole AC-1 contactor at the same current and voltage class.

The 72 A AC-1 rating is the key number: it's the continuous current the main poles can carry in resistive duty. That's the figure that governs the BOM line — not a motor (AC-3) rating, because this contactor is not specified for inductive motor loads. The 4-pole configuration with two normally-open and two normally-closed auxiliary contacts gives flexibility for interlocking or signalling without an add-on block.

Frequently asked questions

What are the key ratings for this contactor?

It's a 4-pole (2NO+2NC) contactor rated 72 A in AC-1 utilisation category at ≤415 V with a 48 V coil. It's designed for resistive loads only — not motor duty. It meets EN/IEC 60947-1, -4-1, and -5-1.

What compliance standards does it meet?

It complies with EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, and the corresponding Chinese GB/T 14048.1, GB/T 14048.4, GB/T 14048.5 standards. It also meets 850 °C glow-wire fire resistance per IEC 60695-2-1.

How do I source this obsolete part?

Submit an RFQ. Since it's obsolete, availability is through surplus and independent channels — we quote against your order.

MPN
LC1E40008E7IN