Skip to main content
Schneider Electric LC1E40008M7IN — Contactors

Schneider LC1E40008M7IN Easy TeSys Contactor, 4P 72A AC-1, O

MPNLC1E40008M7IN
Obsolete

Schneider Electric Easy TeSys Control, LC1E40008M7IN, 4P (2NO+2NC) contactor, AC-1 72A at ≤415 V, 220 V coil, obsolete.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1E40008M7IN — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationResistive load
LC1E40008M7IN — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-1
LC1E40008M7IN — Contacts & Poles
ParameterValue
Pole configuration4P
LC1E40008M7IN — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (6 Gn for 11 ms) Shocks contactor closed (7 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E40008M7IN — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5
LC1E40008M7IN — Mechanical
ParameterValue
Width85 mm
Height127 mm
Depth110 mm

Product details

The Schneider Electric LC1E40008M7IN is a 4-pole contactor from the Easy TeSys Control range, configured 2NO+2NC, rated for AC-1 resistive loads up to 72 A at ≤415 V with a 220 V coil. The part is now listed as obsolete by the manufacturer.

The AC-1 utilisation category means this contactor is rated for switching resistive loads — heaters, lighting banks, or similar non-inductive circuits — not motor starting. The 72 A rating at ≤415 V is the thermal current (Ith) for that duty. The 4-pole arrangement with 2 normally-open and 2 normally-closed contacts gives flexibility for load/control isolation in one package. Storage tolerance extends to -60 to 80 °C. Mechanical robustness is specified for vibration (1.5 Gn open, 3 Gn closed) and shock (6 Gn open, 7 Gn closed) per IEC 60068 — adequate for most fixed industrial machinery but not for mobile equipment or high-vibration applications like presses.

The contactor is designed to EN/IEC 60947-1, -4-1, and -5-1, plus the Chinese GB/T equivalents 14048.1, 14048.4, and 14048.5.

The LC1E40008M7IN is marked obsolete by Schneider Electric. The buyer should verify that the 4P 2NO+2NC configuration and AC-1 72 A rating match the application before committing the BOM line.

Frequently asked questions

What are the key ratings for this contactor?

AC-1 resistive load rating of 72 A at ≤415 V, 4 poles (2NO+2NC), 220 V coil. Mounts on plate or DIN rail. Ambient operation -5 to 55 °C.

What standards does this contactor comply with?

EN/IEC 60947-1, -4-1, -5-1 and GB/T 14048.1, 14048.4, 14048.5. Fire resistance 850 °C per IEC 60695-2-1. IP2X finger protection.

How do I source this obsolete part?

Since it is obsolete, it is sourced to order through independent distribution against an RFQ. No official replacement is listed.

MPN
LC1E40008M7IN