Skip to main content
Schneider Electric LC1E40B10M7 — Contactors

Schneider Electric LC1E40B10M7 Easy TeSys Contactor, 40A AC-

MPNLC1E40B10M7
Active

Schneider Electric Easy TeSys contactor, LC1E40B10M7, 3-pole (3 NO), AC-3 rated 40 A at ≤ 440 V, 220 V AC coil, DIN-rail or plate mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1E40B10M7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationMotor control Resistive load
LC1E40B10M7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-3 AC-3e AC-1
LC1E40B10M7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1E40B10M7 — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor closed (10 Gn for 11 ms) Shocks contactor open (6 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E40B10M7 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ
LC1E40B10M7 — Mechanical
ParameterValue
Width56 mm
Height84 mm
Depth86 mm

Product details

IP2X finger protection means it's safe for open panel work, but it's not a washdown part; keep it inside a cabinet.

The AC-3 rating at 40 A covers most 15–18.5 kW motor loads at 400 V three-phase — that's the real-world current for starting and stopping a motor under load. AC-1 rating handles resistive loads up to the same current if you're switching heaters or lighting banks. The 1.5 ms non-overlap time between NC and NO contacts guarantees break-before-make, which matters for reversing or interlocking circuits where you can't let both coils energise at once.

Frequently asked questions

What are the key ratings for this contactor?

AC-3 rating is 40 A at ≤ 440 V, with a 220 V AC coil. It's a 3-pole (3 NO) contactor, rated for motor control and resistive loads. Depth is 86 mm, width 56 mm, height 84 mm.

What standards does the LC1E40B10M7 comply with?

It complies with EN/IEC 60947-1, -4-1, -5-1, and GB/T 14048.1.4.5. Fire resistance is tested to 850 °C per IEC 60695-2-1, and protective treatment is TH (pollution degree 3) per IEC 60068.

MPN
LC1E40B10M7