LC1E50B6 — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationMotor control Resistive load
LC1E50B6 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-3 AC-3e AC-1
LC1E50B6 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1E50B6 — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (6 Gn for 11 ms) Shocks contactor closed (7 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068-2-30 test Db
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E50B6 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ
LC1E50B6 — Mechanical
ParameterValue
Width75 mm
Height127 mm
Depth114 mm

Product details

It switches 50 A in AC-3 / AC-3e duty at up to 440 V, and carries an AC-1 utilisation category for resistive loads. The coil is 24 V AC at 60 Hz. The 24 V AC coil draws from a control transformer; non-overlap time between NC and NO contacts is guaranteed at 1.5 ms on both energisation and de-energisation, which prevents shoot-through in reversing or star-delta circuits.

Also complies with EN/IEC 60335-1 Clause 30.2 and EN/IEC 60335-2-40 Annex JJ for glow-wire / fire resistance. The contactor passes 850 °C glow-wire test per IEC 60695-2-1, and is protected against damp heat (TH treatment, pollution degree 3) per IEC 60068-2-30.

Dimensions: 127 mm height, 75 mm width, 114 mm depth. Operates at -5 to 55 °C ambient, stores at -60 to 80 °C. Mechanical robustness: 3 Gn vibration closed, 7 Gn shock closed — suitable for panel-mounted use in industrial enclosures subject to moderate vibration.