Skip to main content
Schneider Electric LC1E50F7 — Contactors

Schneider LC1E50F7 Easy TeSys Contactor, 50A AC-3, 110VAC Co

MPNLC1E50F7
Active

Schneider Electric Easy TeSys Control LC1E contactor, 3P, AC-3/AC-3e 50A at ≤440V, 110V AC 50/60Hz coil, obsolete.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1E50F7 — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationMotor control Resistive load
LC1E50F7 — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-3 AC-3e AC-1
LC1E50F7 — Contacts & Poles
ParameterValue
Pole configuration3P
LC1E50F7 — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m without derating
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (6 Gn for 11 ms) Shocks contactor closed (7 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068-2-30 test Db
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E50F7 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5 EN/IEC 60335-1:Clause 30.2 EN/IEC 60335-2-40:Annex JJ
LC1E50F7 — Mechanical
ParameterValue
Width75 mm
Height127 mm
Depth114 mm

Product details

The Schneider Electric LC1E50F7 is a three-pole contactor from the Easy TeSys Control range, rated for motor control in AC-3 and AC-3e duty at 50 A up to 440 V, with a 110 V AC 50/60 Hz coil. It is also listed for resistive loads under AC-1. The part is now classified as obsolete by the manufacturer. The 110 V AC coil is common in North American control circuits; verify your control transformer matches before wiring.

Lifecycle reality — obsolete, not gone

Schneider has marked the LC1E50F7 as obsolete. If you are a quality-doc controller tracking a change, note that the LC1E50F7 carries EN/IEC 60947-4-1 (contactor standard) and EN/IEC 60947-5-1 (control circuit device), plus GB/T equivalents. TH protective treatment per IEC 60068-2-30 covers humid environments.

The contactor is designed to make and break those starting currents without welding. For resistive loads (AC-1), the same poles can carry a higher current, but the exact figure is not listed here. This matters for interlocking circuits where a momentary overlap could short phases — the 1.5 ms window ensures the NC set opens before the NO set closes, and vice versa.

Frequently asked questions

What are the key ratings for the LC1E50F7?

Three-pole contactor rated 50 A in AC-3 and AC-3e duty at ≤440 V, with a 110 V AC 50/60 Hz coil. Also suitable for AC-1 resistive loads. Mounts on DIN rail or plate. Operating temperature range is -5 to 55 °C.

What standards does the LC1E50F7 comply with?

It complies with EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, and the Chinese GB/T equivalents. Fire resistance is tested to 850 °C per IEC 60695-2-1. TH protective treatment per IEC 60068-2-30 covers humid environments.

MPN
LC1E50F7