Skip to main content
Schneider Electric LC1E65004F7IN — Contactors

Schneider Electric LC1E65004F7IN Easy TeSys Contactor, 60A A

MPNLC1E65004F7IN
Active

Schneider Electric Easy TeSys contactor, 4P (2NO+2NC), 60A AC-1, coil 415V AC 50Hz, DIN rail/plate mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1E65004F7IN — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationResistive load
LC1E65004F7IN — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-1
LC1E65004F7IN — Contacts & Poles
ParameterValue
Pole configuration4P
LC1E65004F7IN — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (6 Gn for 11 ms) Shocks contactor closed (7 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E65004F7IN — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5
LC1E65004F7IN — Mechanical
ParameterValue
Width85 mm
Height127 mm
Depth125 mm

Product details

The LC1E65004F7IN is a 4-pole contactor from Schneider Electric's Easy TeSys Control range, built for switching resistive loads under AC-1 utilisation category at up to 60 A. The coil is wound for 415 V AC 50 Hz, so it's a direct fit for European 400 V line-voltage control circuits without a transformer. Rated operational voltage on the power circuit is 10 MOhm for the control circuit — that's the insulation resistance figure, not a working voltage; the contactor handles line voltages up to the standard 415 V AC per the description. Mounting is straightforward: DIN rail or plate, with a 85 mm width and 127 mm height that fits a standard 4-pole contactor footprint.

The 60 A AC-1 rating is the continuous resistive current the main poles can carry — think heaters, lighting banks, or resistive loads where inrush is low. That's not a motor rating; for inductive motor loads you'd need the AC-3 current, which is typically lower on the same frame. The contactor is explicitly listed for resistive load application, so don't spec it for a motor starter without checking the AC-3 curve. The 4-pole configuration is 2NO + 2NC, giving you both normally-open and normally-closed main contacts. That's useful for switching a load and simultaneously breaking a separate circuit — for example, a heater bank with a separate interlock circuit on the NC poles.

The contactor is TH-treated for pollution degree 3 per IEC 60068, meaning it's protected against conductive pollution in industrial atmospheres — a standard spec for factory-floor panels. Mechanical robustness is rated for vibrations up to 3 Gn (closed contacts) and shocks up to 7 Gn (closed), so it holds up on machinery with moderate vibration — conveyors, pumps, compressors.

Frequently asked questions

What is the closest alternative in the same family?

Within the Easy TeSys range, the closest peer would be a 4-pole contactor with the same coil voltage but a different current rating — for example, a 40 A AC-1 version if your load is lighter. There is no pin-compatible drop-in with identical ratings; the LC1E65004F7IN is the 60 A AC-1 variant with a 415 V 50 Hz coil. If you need a different coil voltage (e.g., 230 V or 24 V DC), look at other LC1E order codes in the same frame size.

What are the key dimensions for panel layout?

Width 85 mm, height 127 mm, depth 125 mm. Mounts on DIN rail or directly to a plate. The 4-pole footprint is standard for this class.

What compliance documentation is available?

The contactor is certified to EN/IEC 60947-1, EN/IEC 60947-4-1, EN/IEC 60947-5-1, and the Chinese GB/T equivalents. Fire resistance is tested to 850 °C per IEC 60695-2-1. Protective treatment meets TH (pollution degree 3) per IEC 60068. RoHS and REACH declarations are standard for Schneider's current production parts.

MPN