Skip to main content
Schneider Electric LC1E65004M7IN — Contactors

Schneider LC1E65004M7IN Easy TeSys Contactor, 4P, AC-1 85A,

MPNLC1E65004M7IN
Obsolete

Schneider Electric Easy TeSys Control, LC1E65004M7IN, 4P(4NO) contactor, AC-1 85A at ≤415V, 4220V coil.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

LC1E65004M7IN — Identification
ParameterValue
Product / component typeContactor
Series / rangeEasy TeSys
ApplicationResistive load
LC1E65004M7IN — Ratings & Performance
ParameterValue
Rated operational voltage (Ue)Power circuit: 10 MOhm for control circuit
Utilisation categoryAC-1
LC1E65004M7IN — Contacts & Poles
ParameterValue
Pole configuration4P
LC1E65004M7IN — Environmental
ParameterValue
IP degree of protectionIP2X conforming to IEC 60529
Operating altitude3000 m
Mechanical robustnessVibrations contactor open (1.5 Gn, 5...300 Hz) Vibrations contactor closed (3 Gn, 5...300 Hz) Shocks contactor open (6 Gn for 11 ms) Shocks contactor closed (7 Gn for 11 ms)
Protective treatment / pollution degreeTH (pollution degree 3) conforming to IEC 60068
Fire resistance850 °C conforming to IEC 60695-2-1
LC1E65004M7IN — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-4-1 EN/IEC 60947-5-1 GB/T 14048.1 GB/T 14048.4 GB/T 14048.5
LC1E65004M7IN — Mechanical
ParameterValue
Width85 mm
Height127 mm
Depth125 mm

Product details

The Schneider Electric LC1E65004M7IN is a 4-pole (4 normally-open) contactor from the Easy TeSys Control range, rated for resistive load switching in AC-1 utilisation category at 85 A up to 415 V. It carries a 4220 V control coil and is designed for DIN rail or plate mounting in control panels. Rated operational voltage for the power circuit is specified alongside a 10 MOhm insulation resistance for the control circuit. The contactor meets EN/IEC 60947-1, 60947-4-1, and 60947-5-1, plus the Chinese GB/T equivalents, with IP2X finger protection per IEC 60529.

The AC-1 rating of 85 A at ≤415 V defines the contactor's capacity for resistive loads — heaters, lighting banks, or non-inductive circuits. AC-1 is the least demanding switching duty because there is no motor inrush or inductive arc to manage, so this rating is the maximum continuous current the main poles can carry in that service. For motor loads (AC-3 duty), the rated current would be lower; this part is not specified for that category. The 4-pole configuration with all four contacts normally open suits applications requiring simultaneous switching of multiple resistive circuits or a three-phase load plus a neutral line. The 4220 V control coil voltage is a standard 50/60 Hz AC coil — verify the control supply matches before installation. The operating ambient temperature range is -5 to 55 °C, with storage from -60 to 80 °C, and the device is TH-treated for pollution degree 3 environments.

Frequently asked questions

What are the key ratings for this contactor?

It is a 4-pole (4NO) contactor rated for AC-1 resistive load switching at 85 A up to 415 V, with a 4220 V control coil. It meets EN/IEC 60947 and GB/T standards and is IP2X rated.

How do I source this obsolete part?

Sourcing is handled on a quoted-to-order basis against an RFQ. Because it is obsolete, availability is limited to verified surplus or last-time-buy inventory — no standard franchise stock exists.

MPN
LC1E65004M7IN